background image

8

2. Operation

2.1

Deaerating the unit

•••••

Open the water supply.

•••••

Let the unit run without the high-pressure
hose until the water exits the high-pressure
outlet without bubbles.

•••••

Then, connect the high-pressure hose.

2.2

Working with the high-pressure
nozzle

•••••

The spray angle determines the effectiveness
of the high-pressure spray.
Turn the front safety device of the three-way
nozzle to set the spray angle.

High-pressure pencil jet (0°) for
especially stubborn dirt.

High-pressure fan jet (25°) for
large areas of dirt.

Low-pressure fan jet (CHEM) for
operation with detergent.

•••••

Always start by directing the high-pressure
spray onto the object which is to be cleaned
from a greater distance in order to prevent
damage caused by excessively high pressure.

•••••

Only turn the front safety device of the three-
way nozzle when the spray gun is closed.

2.3

Adjusting the working pressure and
flow rate

•••••

You may infinitely adjust the working pressure
and the flow rate on the Servopress spray
gun. To do this, turn the small adjustment
wheel on the spray gun to the desired position.

•••••

At the lowest flow rate the waste heat from the
motor heats the water by approx. 68 °F (20°C).

2.4

Operation with detergent

•••••

Fill the detergent tank.

•••••

Set the three-way nozzle to " 

 ".

•••••

Set the detergent metering valve to the desired
concentration.

Metering valve setting

 1

 3

 5

 7

Detergent concentration in %
at maximum flow rate

0.5

2.5

5.0

7.0

•••••

We recommend that you use detergent
sparingly for the sake of the environment.
Observe the recommended dosage on the
detergent label.

•••••

We offer you an individual cleaning and
detergent range, thereby guaranteeing fault-
free work. Please allow us to advise you or
order our catalogue or the detergent
information sheets.

Note:
Only those detergents which have been
approved by the appliance manufacturer may
be used. Unsuitable detergents can damage
the appliance and the object being cleaned.

•••••

We recommend the following cleaning
methods:

Step 1: Loosening dirt
Spray on detergent sparingly and leave for
1-5 minutes.

Step 2: Removing dirt
Spray off the loosened dirt with the high-
pressure spray.

•••••

After operating with cleaning agent, you should
set the cleaning agent metering valve to „0“
and flush the unit for approximately 1 minute
with the gun open.

Summary of Contents for HD 1090

Page 1: ...HD 1090 5 956 205 A10828 12 97...

Page 2: ...n ais Page 14 Veuillez lire attentivement la pr sente notice d instructions avant la mise en service et respecter en particulier les Consignes de s curit pour nettoyeurs haute pression Espa ol P gina...

Page 3: ...s necessary when a product is used near children Know how to stop the product and bleed pressure quickly Be thoroughly familiar with the controls Stay alert watch what you are doing Do not operate the...

Page 4: ...ORDS Use only 3 wire extension cords that have 3 prong grounding type plugs and 3 pole cord connectors that accept the plug from the product Use only extension cords that are intended for outdooruse T...

Page 5: ...for Pressure and Flow Regulation 5 High Pressure Hose 6 Handle 7 Detergent Metering Valve 8 Screw Cap for Detergent Tank 9 Detergent Tank 10 Detergent Intake Hose with Filter 11 Fastening Screw for t...

Page 6: ...e appropriate oil traps protection of the environment If the machine is used at petrol stations or in otherhazardousareas theappropriatesafety 1 1 Unpacking the unit If while unpacking you discover da...

Page 7: ...eelonthesprayguntothedesiredposition At the lowest flow rate the waste heat from the motorheatsthewaterbyapprox 68 F 20 C 2 4 Operation with detergent Fill the detergent tank Set the three way nozzle...

Page 8: ...ulled again the appliance switches on again 2 6 Switching off the unit Switch off the unit and pull the electric plug out of the socket Close the water supply Squeeze the lever on the spray gun until...

Page 9: ...d from the front Tip the unit and drain out oil Dispose of used oil at an authorized collec tioncentre protectionoftheenvironment Slowly fill up with new oil Air bubbles must be allowed to escape SeeT...

Page 10: ...three way nozzle to High Pressure Clean replace three way nozzle Clean sieve in the water connection Deaerate the unit Check water supply flow rate see Technical Data Check all pump supply lines for l...

Page 11: ...e pump back on The overflow valve and the pressure switch are factory set and lead sealed Adjustment by customer service only 5 4 Spare Parts A selection of the most common spare parts numbers is list...

Page 12: ...perature of 68 F 20 C ft 3 3 1 m Supply pressure max psi 150 150 1100 kPa Performance data Operating pressure psi 150 3000 150 2250 1100 16100 kPa Flow rate USgpm 1 3 4 0 1 3 4 0 300 900 l h Detergent...

Page 13: ...1 951 841 CDN 5 364 129 0 5 364 129 0 6 386 463 0 1 951 801 USA 1 951 811 USA 1 951 841 USA 1 951 681 USA 4 760 101 0 6 303 025 0 6 303 025 0 5 321 150 0 4 760 101 0 6 303 025 0 6 303 025 0 5 321 150...