10

3. Care and Maintenance

•••••

You may take out a regular safety inspection
contract or service contract with your dealer.
Please discuss this with your dealer.

3.1

Visual check

•••••

Check connection cable

The connection cable must not be damaged
(danger of electrical accident). A damaged
cable must be replaced immediately by
authorized customer service/ electrician.

•••••

Check high-pressure hose

The high-pressure hose must not be damaged
(danger of bursting). A damaged high-
pressure hose must be replaced immediately.

•••••

Check pump for leaks

Three drops per minute are permissible. If the
unit leaks more frequently, contact customer
service.

3.2

Every week

•••••

Check the oil level in the oil tank.
If the oil is milky (water in oil), contact customer
service immediately.

•••••

Clean the sieve at the water connection.

•••••

Clean the filter on the detergent intake hose.

3.3

Annually or after 500 operating
hours

•••••

Change oil.

– Unscrew the oil drain plug from the side of

the motor housing (on the left when viewed
from the front). Tip the unit and drain out
oil.

– Dispose of used oil at an authorized collec-

tion centre (protection of the environment).

– Slowly fill up with new oil.

Air bubbles must be allowed to escape.

– See Technical Data for oil type and amount.

3.4

Protection against freezing

•••••

Freezing may destroy the unit if it has not
been completely drained of water. It is best to
store the unit over winter in a heated area,
otherwise it is recommended to empty the unit
or rinse out thoroughly with an antifreeze.

Emptying the unit

– Unscrew the water supply hose and the

high-pressure hose from the unit.

– Run the unit until the pump and hoses are

empty (max. one minute).

Antifreeze

If the unit is not to be used for prolonged
periods, pump an antifreeze through the unit.
To some extent this will protect the unit against
corrosion.

3.5

Emptying and cleaning the
detergent tank

•••••

Unscrew the fastening screws for the hood.

•••••

Remove the hood.

•••••

Pull out screw cap and suction hose for the
detergent tank.

•••••

Unscrew the fastening nut for the detergent
tank and remove the tank..

•••••

Empty and clean the detergent tank.

Disconnect the unit from the power mains before carrying out any service and

maintenance work.

Summary of Contents for HD 1090

Page 1: ...HD 1090 5 956 205 A10828 12 97...

Page 2: ...n ais Page 14 Veuillez lire attentivement la pr sente notice d instructions avant la mise en service et respecter en particulier les Consignes de s curit pour nettoyeurs haute pression Espa ol P gina...

Page 3: ...s necessary when a product is used near children Know how to stop the product and bleed pressure quickly Be thoroughly familiar with the controls Stay alert watch what you are doing Do not operate the...

Page 4: ...ORDS Use only 3 wire extension cords that have 3 prong grounding type plugs and 3 pole cord connectors that accept the plug from the product Use only extension cords that are intended for outdooruse T...

Page 5: ...for Pressure and Flow Regulation 5 High Pressure Hose 6 Handle 7 Detergent Metering Valve 8 Screw Cap for Detergent Tank 9 Detergent Tank 10 Detergent Intake Hose with Filter 11 Fastening Screw for t...

Page 6: ...e appropriate oil traps protection of the environment If the machine is used at petrol stations or in otherhazardousareas theappropriatesafety 1 1 Unpacking the unit If while unpacking you discover da...

Page 7: ...eelonthesprayguntothedesiredposition At the lowest flow rate the waste heat from the motorheatsthewaterbyapprox 68 F 20 C 2 4 Operation with detergent Fill the detergent tank Set the three way nozzle...

Page 8: ...ulled again the appliance switches on again 2 6 Switching off the unit Switch off the unit and pull the electric plug out of the socket Close the water supply Squeeze the lever on the spray gun until...

Page 9: ...d from the front Tip the unit and drain out oil Dispose of used oil at an authorized collec tioncentre protectionoftheenvironment Slowly fill up with new oil Air bubbles must be allowed to escape SeeT...

Page 10: ...three way nozzle to High Pressure Clean replace three way nozzle Clean sieve in the water connection Deaerate the unit Check water supply flow rate see Technical Data Check all pump supply lines for l...

Page 11: ...e pump back on The overflow valve and the pressure switch are factory set and lead sealed Adjustment by customer service only 5 4 Spare Parts A selection of the most common spare parts numbers is list...

Page 12: ...perature of 68 F 20 C ft 3 3 1 m Supply pressure max psi 150 150 1100 kPa Performance data Operating pressure psi 150 3000 150 2250 1100 16100 kPa Flow rate USgpm 1 3 4 0 1 3 4 0 300 900 l h Detergent...

Page 13: ...1 951 841 CDN 5 364 129 0 5 364 129 0 6 386 463 0 1 951 801 USA 1 951 811 USA 1 951 841 USA 1 951 681 USA 4 760 101 0 6 303 025 0 6 303 025 0 5 321 150 0 4 760 101 0 6 303 025 0 6 303 025 0 5 321 150...