background image

5

  * only  1.951-801 UL

To Test the GFCI

1. Insert the plug into grounded electrical outlet.

2. Press the reset button.

3. Press the test button. The reset button pops up.

4. Press the reset button again for use.

Do not use if the above test fails.

IMPORTANT SAFETY INSTRUCTIONS

GROUNDING INSTRUCTIONS

This product must be grounded. If it should
malfunction or breakdown, grounding provides
a path of least resistance for electric current to
reduce the risk of electric shock. This product is
equipped with a cord having an equipment-
grounding conductor and a grounding plug. The
plug must be plugged into an appropriate outlet
that is properly installed and grounded in
accordance with all local codes and ordinances.

DANGER

- Improper connection of the equipment-

grounding conductor can result in a risk of
electrocution. Check with a qualified
electrician or service personnel if you are
in doubt as to whether the outlet is properly
grounded. Do not modify the plug provided
with the product

- if it will not fit the outlet, have a proper

outlet installed by a qualified electrician.
Do not use any type of adaptor with this
product.

EXTENSION CORDS

Use only 3-wire extension cords that have
3-prong grounding-type plugs and 3-pole cord
connectors that accept the plug from the product.
Use only extension cords that are intended for
outdoor use. These extension cords are identified
by a marking “Acceptable for use with outdoor
appliances; store indoors while not in use.” Use
only extension cords having an electrical rating
not less than the rating of the product. Do not use
damaged extension cords. Examine extension
cord before using and replace if damaged. Do not
abuse extension cord and do not yank on any
cord to disconnect. Keep cord away from heat
and sharp edges. Always disconnect the
extension cord from the receptacle before
disconnecting the product from the extension
cord.
Important:  When using an extension cord always
unwind cord completely.

WARNING

To reduce the risk of electrocution, keep all
connections dry and off the ground. Do not
touch plug with wet hands.

WARNING

Risk of Injection or Injury
- Do Not Direct Discharge Stream At Persons.

High Pressure jets can be dangerous if subject to
misuse. The jet must not be directed at persons,
animals or machine itself. This machine has
been designed for use with cleaning chemicals
supplied or recommended by the manufacturer.
The use of other cleaning chemicals may affect
the operation of the machine and void the
warranty.

Summary of Contents for HD 1090

Page 1: ...HD 1090 5 956 205 A10828 12 97...

Page 2: ...n ais Page 14 Veuillez lire attentivement la pr sente notice d instructions avant la mise en service et respecter en particulier les Consignes de s curit pour nettoyeurs haute pression Espa ol P gina...

Page 3: ...s necessary when a product is used near children Know how to stop the product and bleed pressure quickly Be thoroughly familiar with the controls Stay alert watch what you are doing Do not operate the...

Page 4: ...ORDS Use only 3 wire extension cords that have 3 prong grounding type plugs and 3 pole cord connectors that accept the plug from the product Use only extension cords that are intended for outdooruse T...

Page 5: ...for Pressure and Flow Regulation 5 High Pressure Hose 6 Handle 7 Detergent Metering Valve 8 Screw Cap for Detergent Tank 9 Detergent Tank 10 Detergent Intake Hose with Filter 11 Fastening Screw for t...

Page 6: ...e appropriate oil traps protection of the environment If the machine is used at petrol stations or in otherhazardousareas theappropriatesafety 1 1 Unpacking the unit If while unpacking you discover da...

Page 7: ...eelonthesprayguntothedesiredposition At the lowest flow rate the waste heat from the motorheatsthewaterbyapprox 68 F 20 C 2 4 Operation with detergent Fill the detergent tank Set the three way nozzle...

Page 8: ...ulled again the appliance switches on again 2 6 Switching off the unit Switch off the unit and pull the electric plug out of the socket Close the water supply Squeeze the lever on the spray gun until...

Page 9: ...d from the front Tip the unit and drain out oil Dispose of used oil at an authorized collec tioncentre protectionoftheenvironment Slowly fill up with new oil Air bubbles must be allowed to escape SeeT...

Page 10: ...three way nozzle to High Pressure Clean replace three way nozzle Clean sieve in the water connection Deaerate the unit Check water supply flow rate see Technical Data Check all pump supply lines for l...

Page 11: ...e pump back on The overflow valve and the pressure switch are factory set and lead sealed Adjustment by customer service only 5 4 Spare Parts A selection of the most common spare parts numbers is list...

Page 12: ...perature of 68 F 20 C ft 3 3 1 m Supply pressure max psi 150 150 1100 kPa Performance data Operating pressure psi 150 3000 150 2250 1100 16100 kPa Flow rate USgpm 1 3 4 0 1 3 4 0 300 900 l h Detergent...

Page 13: ...1 951 841 CDN 5 364 129 0 5 364 129 0 6 386 463 0 1 951 801 USA 1 951 811 USA 1 951 841 USA 1 951 681 USA 4 760 101 0 6 303 025 0 6 303 025 0 5 321 150 0 4 760 101 0 6 303 025 0 6 303 025 0 5 321 150...