Directive 24: Set ADEMCO account
In installer program state,
Press
[
24
]
+
[
OK
]
+
[
Account 4 digits
]
+
[
OK
]
Note: when networking with ADEMCO center, the code should be 4 bits (0000-9999)
No account by default
Directive 26: Set wireless siren
In installer program state,
Press
[
26
]
+
[
OK
]
+
[
wireless siren code 8 digits
]
+
[
OK
]
Note: the 8 digits siren code is marked at the back of siren
If you want to erase siren code, in installer program state, press
[
26
]
+
[
OK
]
+
[
#
]
+
[
OK
]
No wireless siren code by default
Directive 27: Open/Close phone line -cutting report function
In installer program state,
Press
[
27
]
+
[
OK
]
+
[
0 or 1
]
+
[
OK
]
, 0 for close report, 1 for open report.
Close report by default
Directive 30: Set zone attribute
In installer program state,
Press
[
30
]
+
[
OK
]
+
[
xxxxxxxx
]
+
[
OK
]
, x is zone attribute of each zone. 8 x is for 8 zones
X value scale ,you can see attribute table below
Note:
1.Zone attribute depends on detector types.
2.Fire alarm, Gas alarm, Emergency alarm and Medical alarm are treated as 24 hours per day. It is not
control by Arm/Disarm.
3.Vacant zone or no used zone can be bypass.
4.The zone attribute number should be 8 digits
5.If zones are set to doorbell zone in attribute, it is only for door alert, no alarm and can't dial alarm
phone numbers.
All zones attribute are set to be Intrusion alarm by default.
Attribute table
Code
Zone Attribute
0
Bypass
1
Fire Alarm
2
Gas Alarm
3
Emergency Alarm
4
Medical Alarm
5
Intrusion Alarm
6
Perimeter
7
Door-bell
Directive 31: Set wired zone respond time
In installer program state,
Press
[
31
]
+
[
OK
]
+
[
xxxxxxxx
]
+
[
OK
]
, X means response time for zone 1 to 8 zone.
X value please see table below