background image

 

 
 
 
 

 

INTEGRA ARINC e-NAV 

DESCRIPTION, INSTALLATION, 

OPERATION MANUAL 

PAGE: 13 of 14 
REF.: DOC13033 
INDEX: B 
DATE: SEP 14/2016

 

 

© Orolia S.A.S.

 

7.  CONNECTING DIAGRAM 

NOTE: RCP mating connectors and relevant RCP pin-out inputs are defined in 
the INTEGRA ELT initial installation Manual supplied with the ELT. 

For  complete  instructions  and  specifications,  this  manual  can  be  found  on 
Kannad Aviation download area. 

 

Figure 7: Connecting Diagram 

 

 

Summary of Contents for INTEGRA ARINC e-NAV

Page 1: ...520 GUIDEL FRANCE Telephone 33 0 2 97 02 49 49 Fax 33 0 2 97 65 00 20 Web http www mcmurdogroup com E mail info mcmurdogroup com REF DOC13033 INDEX B DATE SEP 14 2016 INTEGRA ARINC e NAV DESCRIPTION I...

Page 2: ...S A S Users are kindly requested to notify Orolia S A S of any discrepancy omission or error found in this manual Please report to our customer support E mail support mcmurdogroup com Tel 33 0 2 97 0...

Page 3: ...4 Connection to INTEGRA ER N ELT 5 4 FIRST POWER UP PROCEDURE 6 4 1 Check of the ELT 6 4 2 Check of on board GPS equipment 6 4 3 Position Data Verification 6 4 3 1 Tester Connection 6 4 3 2 Test prep...

Page 4: ...IGURES Figure 1 INTEGRA ARINC e NAV Overview 1 Figure 2 Example of INTEGRA ARINC e NAV installed on Mounting Bracket 2 Figure 3 INTEGRA ARINC e NAV Concept 3 Figure 4 INTEGRA ARINC e NAV Installation...

Page 5: ...the 406 MHz distress message as soon as the ELT is activated This manual contains information to install and operate the INTEGRA ARINC e NAV Part Number S1850581 01 1 2 INTEGRA ARINC e NAV Presentati...

Page 6: ...specific INTEGRA ELT mounting bracket Bracket Universal for INTEGRA ARINC e NAV for ELT AP P N S1850551 01 when connect to an AP INTEGRA ER N or AP H INTEGRA ER N ELT or Bracket Universal for INTEGRA...

Page 7: ...olia S A S 1 3 Concept The 19 Pin male socket has to be connected to 3 separate cables On Board 28 VDC power supply ARINC frames of the On Board GPS equipment DIN 12 plug of the ELT In addition the EL...

Page 8: ...s supports either with its connector on the left side or on the right side 2 Fix the INTEGRA ARINC e NAV onto the mounting bracket with the 2 captive screws and tighten to a torque of 1 4 Newton per m...

Page 9: ...e ELT Wires of AWG24 gauge should be preferred A 19 Pin female plug reference SOURIAU 851 06 R 14 19 S 50 shall be used to connect the INTEGRA ARINC e NAV this plug is not provided Figure 5 19 Pin fem...

Page 10: ...nk of the aircraft GPS equipment is activated refer to the GPS equipment relevant manual 2 Switch the GPS equipment to ON 3 Wait for the acquisition of a GPS valid position on the GPS equipment 4 3 Po...

Page 11: ...LT in aluminum or copper foil 4 3 3 Validation Procedure NOTE For ELT operation refer to the relevant ELT Operation Manual 1 After having performed all wiring tasks as indicated in Section 3 INTEGRA A...

Page 12: ...ata Protocols Unique ELT Serial Number 4 minutes User Location 1 4 seconds Standard Location Aircraft Operator Designator Serial Number 4 minutes User Location 1 4 seconds Standard Location Aircraft 2...

Page 13: ...m a self Test by switching ELT to OFF then to ARM After 5 seconds the LED of INTEGRA ARINC e NAV switches ON GREEN 28V DC is correct and ARINC Frame is valid Red 28V DC is not correct and or ARINC Fra...

Page 14: ...d longitude are encoded on 21 bits and use both Data field bits 29 11 and SDI field 10 and 9 bits Parity bit can be checked or not by INTEGRA ARINC e NAV ARINC RX1 ARINC positive input ARINC RX2 ARINC...

Page 15: ...ompression ED 62A SPECIAL 4 6 2 As per ED 62A Overpressure 4 4 3 ED 62A 4 6 3 As per ED 62A Temperature variation 5 B Humidity 6 C Ops shocks and crash safety ED 62A SPECIAL 7 As per ED 62A Vibrations...

Page 16: ...ratures Specifications Operating 40 C to 55 C Class 1 Storage 55 C to 85 C 6 5 Electrical Characteristics Power supply Aircraft 28 VDC Consumption 7 mA typical 12 5 mA max 28 V established mode 300 mA...

Page 17: ...2016 Orolia S A S 7 CONNECTING DIAGRAM NOTE RCP mating connectors and relevant RCP pin out inputs are defined in the INTEGRA ELT initial installation Manual supplied with the ELT For complete instruct...

Page 18: ...TEGRA ARINC e NAV DESCRIPTION INSTALLATION OPERATION MANUAL PAGE 14 of 14 REF DOC13033 INDEX B DATE SEP 14 2016 Orolia S A S 8 SERVICING Maintenance is on demand only No periodic inspection is require...

Page 19: ......

Page 20: ...Orolia S A S Orolia S A S Z I des Cinq Chemins CS10028 56520 GUIDEL FRANCE Phone 33 0 2 97 02 49 49 Fax 33 0 2 97 02 65 00 20 Website www mcmurdogroup com Email info mcmurdogroup com DOC13033B...

Reviews: