SP-HDBT1X4
12
Note:
To control HDBaseT Splitter via RS232 port, the communication protocol
parameters should be configured in the right manner: Baud rate: 9600; Data bit: 8; Stop
bit: 1; Parity bit: none.
4.2.3 Control far-end device from local
Connect the RS232 ports of HDBaseT Splitter and Twisted Pair PoC Receiver (See
Figure 4-3), and then it is capable to control HDBaseT Splitter and far-end device from
local by sending RS232 commands.
Figure 4- 3 Control far-end device from local
4.2.4 Control local device from remote
Connect the RS232 ports of HDBaseT Splitter and Twisted Pair PoC Receiver (See
Figure 4-4), and then it is capable to control HDBaseT Splitter or local displayer from
remote by sending RS232 commands.
Summary of Contents for SP-HDBT1X4