ANALYSER LAYOUT & FEATURES 

 
 
 
 
 
 

Summary of Contents for KANE251

Page 1: ...KANE251 Combustion Analyser Stock No 19462 July 2014 Kane International Ltd...

Page 2: ...USING THE FOUR FUNCTION BUTTONS 9 11 7 USING BUTTONS 11 8 USING THE ROTARY DIAL STARTING FROM MENU 12 13 9 MEASURING FLUE GASES 14 20 10 EXAMPLE PRINTOUTS IN AMBIENT AIR 21 22 11 WHEN YOU FINISH USIN...

Page 3: ...Page 3 15 ELECTROMAGNETIC COMPATIBILITY 31 16 END OF LIFE DISPOSAL 31 APPENDIX 1 MAIN PARAMETERS 32 33 APPENDIX 2 SYMBOLS USED ON THE DISPLAY 34 PRODUCT REGISTRATION 35 36...

Page 4: ...a time and all data can be printed via an optional infrared printer The printed data can be live data frozen data or stored data 20 sets of tests can be stored Two lines of 16 characters can be added...

Page 5: ...Page 5 ANALYSER LAYOUT FEATURES...

Page 6: ...Page 6...

Page 7: ...ted with the correct battery polarity Replace the battery cover and the protective rubber cover Switch the analyser on and check that the analyser s date and time are correct To reset the date and tim...

Page 8: ...nalyser s flue gas inlet and connect the flue probe s temperature connector to the T1 socket check the plug s orientation is correct otherwise incorrect temperature measurements will occur see Page 6...

Page 9: ...ument is also exposed to a known gas mixture but is allowed to settle to a steady figure and the reading adjusted to the stated gas concentration of the test gas 6 USING THE FOUR FUNCTION BUTTONS Swit...

Page 10: ...ze function Press the backlight button for 2 seconds to switch on the analysers display backlight Press the backlight button for 2 seconds to disable the backlight NOTE Use of the backlight significan...

Page 11: ...itched on ready to accept data and the infa red receiver is inline with the emitter of the analyser on top of the analyser Storing Data Press and hold the SEND PRINT button for approximately 2 seconds...

Page 12: ...t 6 Header 2 lines each of up to 16 characters that appear on the printout Use ENTER and UP DOWN 7 Gross or Net or Condensing Boiler Furnace efficiency 8 ppm or mg m3 9 Report 10 Printing select the P...

Page 13: ...Fg or EFFc as selected by the user CO2 CO Displays Carbon Dioxide in and Carbon Monoxide in ppm RATIO Displays the CO CO2 ratio and the selected fuel type TEMP Displays the flue Tf and inlet Ti temper...

Page 14: ...probe s maximum temperature Do not exceed the meter s internal temperature operating range Do not put the meter on a hot surface Do not exceed the water trap s levels Do not let the meter s particle f...

Page 15: ...ges of 2 lines and can be set by the user They remain the AUX parameters until changed by the user Press the SEND PRINT button for 1 second to print the full combustion test Press and hold the SEND PR...

Page 16: ...ton for 1 second to print the full combustion test Press and hold the SEND PRINT button for approximately 2 seconds to store the combustion test in the memory Press the BACKLIGHT key for one second to...

Page 17: ...2 seconds to store the combustion test in the memory Press the BACKLIGHT key for one second to freeze the readings before printing Fuel display SET FUEL Set the fuel source NATU GAS Fuel source curre...

Page 18: ...constant 0 000 Set fuel constant Use the scroll to the correct value Press the button to select USER Set the User Fuel calorific value K2 Set fuel constant Press the button to select K2 DONE will be...

Page 19: ...ay K3 Fuel constant 0 000 Set fuel constant Use the scroll to the correct value Press the button to select DONE will be briefly displayed on the bottom line of the display USER Fuel Source EXIT Exit P...

Page 20: ...n for 1 second to print the full combustion test Press and hold the SEND PRINT button for approximately 2 seconds to store the combustion test in the memory Press the BACKLIGHT key for one second to f...

Page 21: ...OUR COMPANY NAME PHONE NUMBER HERE SERIAL NO 000000000 DATE 01 07 14 TIME 12 00 08 COMBUSTION FUEL NAT GAS O2 20 9 CO2 00 0 CO ppm 000 CO ppm n 000 02 REF 00 0 C a l d u e o n 0 1 0 7 1 5 CO CO2 0 000...

Page 22: ...V 1 00B YOUR COMPANY NAME PHONE NUMBER HERE SERIAL NO 000000000 LOG 001 DATE 01 07 14 TIME 12 00 08 COMBUSTION FUEL NAT GAS O2 20 9 CO2 00 0 CO ppm 000 CO ppm n 000 02 REF 00 0 C a l d u e o n 0 1 0 7...

Page 23: ...WILL BE HOT and let it cool Do not put the probe in water which will be sucked into the meter damaging its pump and sensors When the meter s readings return to ambient levels switch it off The meter c...

Page 24: ...lyser not running on mains adapter Batteries exhausted AC charger not giving correct output Fuse blown in charger plug Analyser does not respond to flue gas Particle filter blocked Probe or tubing blo...

Page 25: ...quire more frequent re certification Kane International has service facilities at Atherton near Manchester Tel 01942 873434 the primary service centre for UK customers and at Welwyn Garden City in Her...

Page 26: ...ertfordshire AL7 1JG Sending your analyser Once the analyser has been securely packed then your package is ready for shipment back to Kane If you do not have an account with a courier company you can...

Page 27: ...ent Kane International Ltd Gibfield Park Avenue Atherton Manchester M46 0SY Southern Service Department Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Northern...

Page 28: ...Page 28...

Page 29: ...ensor 0 600 C 0 1 C 2 C 0 3 reading Flue Gas Measurement Oxygen 2 0 21 0 1 0 3 Carbon Monoxide H2 compensated 0 20ppm 21 4 000ppm nom 4 001 10 000ppm 20 000ppm max for 15 mins 1ppm 3ppm 5 of reading 1...

Page 30: ...h 200mm 7 8 long stainless steel shaft type K thermocouple and 3m 6ft long neoprene hose Ambient Operating Range 0 C to 40 C 32 104 F 10 to 90 RH non condensing Storage Capacity 20 sets of test result...

Page 31: ...rence or switch off if possible the offending equipment during your test At the time of writing this manual July 2014 Kane International Ltd are not aware of any field based situation where such inter...

Page 32: ...or INLET temperature from the measured FLUE temperature Displays in either Fahrenheit F or Centigrade C or and will display if the flue probe is not connected COp Carbon Monoxide reading displayed in...

Page 33: ...lable in When the LO BAT symbol appears this indicates the batteries are at less than 10 of charge and should be replaced readings may be affected if used with low power batteries Warning all stored r...

Page 34: ...ency TF Flue temperature TI Inlet temperature T Nett temperature EfG Gross efficiency EfN Nett efficiency EfC Condensing efficiency PO Pump off O Calculated oxygen greater than 18 so calculation is di...

Page 35: ...b Title Company Name Company Address 1 Address 2 Town City County Postcode Country Phone Number Fax Number Mobile Number Email Address Product Details Note Proof of Purchase may be required for warran...

Page 36: ...about Kane Magazine Advert Trade Counter Training School Previous Owner Personal Recommendation Internet Search Exhibition Other Which do you read most often Often Sometimes Hardly Ever Registered Ga...

Page 37: ...Page 37...

Page 38: ...Page 38...

Page 39: ...Page 39...

Page 40: ...g the details below UK Office Keison Products P O Box 2124 Chelmsford Essex CM1 3UP England Tel 44 0 330 088 0560 Fax 44 0 1245 808399 Email sales keison co uk Please note Product designs and specific...