11. ANALYSER SPECIFICATION
(NOTE MAY BE SUBJECT TO CHANGE)
Parameter
Resolution
Accuracy
Range
Temp Measurement
Flue Temperature
Inlet Temperature
Temp (Nett)
*2
1.0
°
C/F
1
°
C/F
1.0
°
C/F
+2.0
°
C (5
°
F)
+0.3% reading
+1°C/F
±0.3% reading
+2
°
C (5
°
F)
+0.3% reading
0-600
°
C
32-1112
°
F
0-100°C
32-212°F
0-600
°
C
32-1112
°
F
Pressure Measurement
0.1
Pa
0.1
Pa
1
Pa
0.01 hPa
+0.5 Pa
+3 Pa
+ 3% of reading
+ 3% of reading
+ 20 Pa
+ 100 Pa
+ 2000 Pa
+ 80 hPa
Gas Measurement
Oxygen
Carbon Monoxide
(KANE450CO)
(KANE450COH)
Nitric Oxide (NO)
Carbon Dioxide
*2
Efficiency
*2
Excess Air
*2
0.1%
1ppm
1ppm
1 ppm
0.1%
0.1%
0.1%
+0.2%
*1
+10ppm <100ppm
*1
+5% of reading
+20ppm <400ppm
+5% <5000ppm
+10% >5000ppm
+ 2ppm <30ppm
*1
+5 ppm > 30ppm
+0.3% reading
+1.0% reading
+0.2%
0-21%
0-2000ppm nom
4000ppm max
for 15 minutes
0-10,000ppm
0 to 100 ppm
0-30%
0-99.9%
0-250%
Pre-programmed Fuels
Natural gas, Light Oil, Propane, Butane, LPG, Wood Pellets.