Summary of Contents for 3500

Page 1: ...KANE3500 Pressure Meter Stock No 18854 2 June 2014 Kane International Ltd...

Page 2: ...optional infrared printer The printed data can be live data frozen data or stored data 255 sets of tests can be stored in non volatile memory Two lines of 20 characters can be added to the header of p...

Page 3: ...anual Page 3 UP DOWN Press either to change the bottom line of the display ENTER Press to cancel OFF The buttons and also change settings such as date time and other menu items when MENU mode has been...

Page 4: ...sure what the maximum pressure might be Always ensure that the meter you are using is correctly rated for the pressure that you intend to measure Excessive pressure 5 times nominal range can permanent...

Page 5: ...aximum number of decimal places LOW one less decimal place displayed PS UNITS mBAR inH2O hPa mmHg PSI kPa Pa mmH2O SETUP Temperature units o F or o C AUTO OFF adjusts the auto power off time A setting...

Page 6: ...pressed Storage capacity is 255 sets of results AUTO STO Automatically stores readings at a preset interval Press then select YES or NO If YES set the desired time interval between 2 and 99 seconds an...

Page 7: ...ceed the meter s operating specifications Do not exceed the meter s internal temperature operating range Do not put the meter on a hot surface When taking critical draft measurements always re zero th...

Page 8: ...very low pressure or draft levels for maximum accuracy re zero the meter in the orientation that it is being used This eliminated gravity effects on the very sensitive pressure transducer It is also r...

Page 9: ...t re calibration Calibration is performed in firmware and there are no user accessible adjustments or user serviceable parts 6 SPECIFICATION Model KANE3500 1 Nominal Pressure Ranges mBar mmH2O Pa kPa...

Page 10: ...00 0 4000 32000 40 00 PSI mmHg hPa inH20 5 000 300 0 400 0 150 0 Model KANE3500 15 Nominal Pressure Ranges mBar kPa PSI 1040 0 100 00 15 00 mmHg hPa inH20 780 0 1040 0 400 0 Model KANE3500 30 Nominal...

Page 11: ...1 Pa 3 of reading 80 hPa 0 01 hPa 3 of reading Model KANE3500 2 Max overrange without damage to sensor is 5 times nominal range Range Resolution Accuracy 20 Pa 0 3 Pa 2 Pa 2000 Pa 0 3 Pa 5 Pa 160 hPa...

Page 12: ...1 hPa 3 of reading Model KANE3500 30 Max overrange without damage to sensor is 5 times nominal range Range Resolution Accuracy 1076 hPA 0 1 hPa 10 hPa 2070 0 hPA 1 hPa 3 of reading Dimensions Weight 2...

Page 13: ...bance is acceptable If not acceptable adjust the meter s position to minimize interference or switch off if possible the offending equipment during your test At the time of writing this manual June 20...

Page 14: ...hr clock Time is recorded when each test is stored printed NOTE When changing the batteries on the instrument the memory will store the date and time for up to one minute if outside this time it may b...

Page 15: ...1JG Sending your KANE3500 Once your KANE3500 has been securely packed then your package is ready for shipment back to Kane If you do not have an account with a courier company you can take your packag...

Page 16: ...e International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Southern Service Centre Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Sou...

Page 17: ...City Hertfordshire AL7 1JG Your Details Name Job Title Company Name Company Address 1 Address 2 Town City County Postcode Country Phone Number Fax Number Mobile Number Email Address Product Details N...

Page 18: ...you hear about Kane Magazine Advert Trade Counter Literature Personal Recommendation Internet Exhibition Other Which do you read most often Often Sometimes Hardly Ever Registered Gas Engineer Gas Inst...

Page 19: ...KANE3500 Manual Page 19...

Page 20: ...KANE3500 Manual Page 20 Thank you for buying this pressure meter Before use please register on our website www kane co uk or complete detach and return the Product Registration page...