Page
12
Check the required functions. All the selected functions will run when
Auto-Program (F5)
is used.
If
Program Fuses
is available and checked, then another dialog box will appear after this list is
closed where you can set device specific fuses.
Note
: Erase the device before programming unless you are adding extra data to existing data in
the device. If you are changing data then you cannot change any programmed bit from a 0 to a 1
without erasing the device first. You can however, change a bit from a 1 to a 0. So BB could be
changed to AA for example but AA cannot be changed to BB. You will not be able to program the
device if the write lockbit has been set.
Warning:
Setting Lockbits may mean that you will be unable to perform further verification on the
device, and disable further writing to the device, You will be able to re-use the device if you
perform an erase.