5 Electrical connection
5.1 Connection of temperature sensors
Temperature sensors are connected to MULTICAL® 803 via the screw terminals on the connection
PCB. It is possible to use both 4-wire and 2-wire sensor types. When using 2-wire sensors, it is
important to mount the supplied jumper on the pins marked with 2-W, located directly above the
screw terminals on the connection PCB. If the supplied jumper is lost, it is possible to terminate
the extra connection terminals by short-circuiting them in pairs as illustrated in red in the table
below.
2-wire
4-wire
Sensor
Terminal number
Illustration
Terminal number
Illustration
t1
1
5
5
6
1
1
2
5
6
5
6
2
6
2
t2
3
7
7
8
3
3
4
7
8
7
8
4
8
4
t3
51
51A
51A
52A
51
51
52A
51A
52
51A
52A
52
52A
52
t4
20
20A
20A
21A
20
20
21
20A
21A
20A
21A
21
21A
21