7 Information code
MULTICAL® constantly monitors a number of important
functions. If errors occur in the measuring system or installation,
a flashing “INFO” appears in the display. The “INFO” field keeps
flashing as long as the error is present, no matter which reading
you choose. The “INFO” field automatically switches off when
the error has been corrected. For indicating current errors in
MULTICAL®, it is possible to scroll to the information code in the
display, this is the display in which INFO does not flash, but is
shown permanently. The information code display is available
both in the USER loop and TECH loop. The info code consists of 8
digits, and each functionality has its own digit dedicated to the
indication of relevant information. For instance all information
concerning temperature sensor t1 is shown in the display as the
second digit from the left.
Display digit
Description
1
2
3
4
5
6
7
8
Info
t1
t2
t3
V1
V2
In-A In-B
1
No voltage supply
2
Low battery level
9
External alarm (e.g. via KMP)
1
t1 Above measuring range or switched off
1
t2 Above measuring range or switched off
1
t3 Above measuring range or switched off
2
t1 Below measuring range or short-circuited
2
t2 Below measuring range or short-circuited
2
t3 Below measuring range or short-circuited
9
9
Invalid temperature difference (t1-t2)
1
V1 Communication error
1
V2 Communication error
2
V1 Wrong pulse figure
2
V2 Wrong pulse figure
3
V1 Air
3
V2 Air
4
V1 Wrong flow direction
4
V2 Wrong flow direction
6
V1 Increased flow
6
V2 Increased flow
7
Burst, water runs out of the system
7
Burst, water runs into the system
8
Leakage, water runs out of the system
8
Leakage, water runs into the system
7
Pulse input A2 Leakage in the system
8
Pulse input A1 Leakage in the system
9
Pulse input A1/A2 External alarm
7
Pulse input B2 Leakage in the system
8
Pulse input B1 Leakage in the system
9
Pulse input B1/B2 External alarm