MULTICAL®
603
Kamstrup
A/S
∙
Technical
description
∙
5512
‐
2029_A1_GB_06.2017
115
configuration
to
the
values
received
from
ULTRAFLOW®
X4.
Auto
Detect
is
initiated
when
the
calculator
top
and
base
are
separated
and
reassembled.
8.1.1.1
Auto
Detect
with
one
ULTRAFLOW®
X4
on
V1
To
use
the
Auto
Detect
functionality
between
MULTICAL®
603
and
ULTRAFLOW®
X4,
follow
the
procedure
below.
①
Break
the
installation
seal
1
,
and
separate
the
calculator’s
top
and
base
②
Mount
ULTRAFLOW®
X4
on
input
V1
in
MULTICAL®
603
as
stated
in
the
table
in
paragraph
8.1
③
Assemble
the
calculator’s
top
and
base
④
Typical display duration 5 s
Note
the
flashing
display
on
MULTICAL®
603,
indicating
that
a
search
for
ULTRAFLOW®
X4
is
being
performed
⑤
Display duration 5 s
Note
the
static
display
on
MULTICAL®
603,
indicating
that
ULTRAFLOW®
X4
has
been
found
and
registered
successfully
2
⑥
MULTICAL®
603
automatically
changes
to
the
primary
energy
display
in
the
USER
loop
1
Remember to re‐establish the installation seal after completed Auto Detect.
2
A configuration logging is carried out each time MULTICAL® 603 registers a change to qp of ULTRAFLOW® X4 on V1.