MULTICAL®
603
Kamstrup
A/S
∙
Technical
description
∙
5512
‐
2029_A1_GB_06.2017
33
The
below
‐
mentioned
table
lists
the
tariff
types,
for
which
MULTICAL
603
can
be
configured
and
shows
the
tariff
types
available
for
each
meter
type.
EE=00
No
active
tariff
If
no
tariff
function
is
required,
you
select
the
set
‐
up
EE=00.
The
tariff
function
can,
however,
at
a
later
stage
be
activated
through
reconfiguration
via
METERTOOL
HCW
(see
Technical
description
5512
‐
2096).
EE=11
Power
‐
controlled
tariff
If
the
current
power
(P)
exceeds
TL2
but
is
lower
than
or
equal
to
TL3,
energy
is
counted
in
TA2
parallel
to
the
main
register.
If
the
current
power
exceeds
TL3
but
is
lower
than
or
equal
to
TL4,
energy
is
counted
in
TA3
parallel
to
the
main
register.
If
the
current
power
exceeds
TL4,
energy
is
counted
in
TA4
parallel
to
the
main
register.
P
TL2
Accumulation
in
main
register
only
TL4
TL3
TL2
TL3
P
TL2
Accumulation
in
TA2
and
main
register
TL4
P
TL3
Accumulation
in
TA3
and
main
register
P
TL4
Accumulation
in
TA4
and
main
register
Setting
up
data,
TL3
must
be
higher
than
TL2
and
TL4
must
be
higher
than
TL3.
The
power
controlled
tariff
is
e.g.
used
as
a
basis
for
the
individual
heat
consumer’s
connection
fee.
Furthermore,
this
tariff
type
can
provide
valuable
statistical
data
if
the
heating
station
considers
new
construction
activities.
EE=
Tariff
type
Function
Heat
meter
Meter
type
2
Heat/
coo
lin
g
meter
Meter
type
3
Heat
meter
Meter
type
4
C
o
ol
ing
meter
Meter
type
5
Heat/
coo
lin
g
meter
Meter
type
6
V
olu
me
meter
Meter
type
7
00
No
active
tariff
No
function
11
Power
tariff
Energy
is
accumulated
in
TA2,
TA3
and
TA4
on
the
basis
of
the
power
limits
entered
in
TL2,
TL3
and
TL4
12
Flow
tariff
Energy
is
accumulated
in
TA2,
TA3
and
TA4
on
the
basis
of
the
flow
limits
entered
in
TL2,
TL3
and
TL4
13
t1
‐
t2
tariff
Energy
is
accumulated
in
TA2,
TA3
and
TA4
on
the
basis
of
the
t
‐
limits
entered
in
TL2,
TL3
and
TL4
14
Inlet
temperature
tariff
Energy
is
accumulated
in
TA2,
TA3
and
TA4
on
the
basis
of
the
t1
‐
limits
entered
in
TL2,
TL3
and
TL4.
15
Outlet
temperature
tariff
Energy
is
accumulated
in
TA2,
TA3
and
TA4
on
the
basis
of
the
t2
‐
limits
entered
in
TL2,
TL3
and
TL4.
19
Time
controlled
tariff
TL2=Start
time
of
TA2
TL3=Start
time
of
TA3
TL4=Start
time
of
TA4
20
Heat/cooling
volume
tariff
(TL2,
TL3
and
TL4
are
not
used)
Volume
(V1)
is
divided
into
TA2
for
heat
(t1
t2)
and
TA3
for
cooling
(t1
t2).
For
heat/cooling
meters,
meter
types
3
and
6,
the
energy
accumulation
also
depends
on
Θ
HC
(TA4
is
not
used
in
this
tariff
type).
21
PQ
‐
tariff
Energy
at
P
TL2
is
saved
in
TA2,
and
energy
at
Q
TL3
is
saved
in
TA3