TECHNICAL DESCRIPTION flowIQ® 3100
8
Kamstrup A/S • Technical Description • 5512
-
1242_B1_GB • 05.2015
At Q4 this results in a pressure loss of max. 0.1 MPa (1 bar).
2.2
Electrical data
Battery
3
.65 VDC,
one C-
cell lithium
Battery lifetime
16
years at t
BAT
< 30°C
EMC data
Fulfil MID class E1 and E2
2.3
Mechanical
data
Accuracy class
2
Ambient class
Fulfils
OIML R49
class B and C (indoors and outdoors)
Mechanical environment
MID class M1
Ambient temperature
2…55°C
Protection class
IP68
Weight
see table
in section
5.1
- Dimensions
Pressure stage
Threaded meter
:
PN16
Flange meter:
PN25
Temperature of medium
0
.
1…30°C (T30) eller 0
.1…50°C (T50)
Storage temperature
-
25…60°C (
drained flow sensor)
2.4
Material
Wetted parts
Meter tube,
with thread
,
DZR brass –
CW511L (resistant to dezincification )
Meter tube,
with
flange
Stainless steel
1.4408
O-ring / gasket
EPDM
Measuring tube
Polyphenylen
e sul
ph
ide PPS – 40 % fibreglass
Reflectors
Stainless steel, W.no. AISI 316, 1.4306, 1.4401
Meter
Meter
housin
g
P
olyphenylene sulphide
– 40 % fibreglass
Cover
Glass
Top ring (sealing)
Polycarbonate (dyed – blue)