12 / 14 channel DMX mode 

 

 

 

 
 
 
 
 

 
 
 
 
 

 
 
 
 
 
 

 
 
 
 

Channel 

Value 

Function 

 

000-255 

Full dimmer 0 - 100%

 

 

000-255 

Strobe, slow to fast

 

000-255 

First head, Y axis position 

000-007 

First head colour select 

008-024 

Red 

025-041 

Blue 

042-057 

Green 

058-074 

White 

075-090 

Red & green 

091-107 

Red & blue 

108-123 

Red & white 

124-140 

Green & blue 

141-156 

Green & white 

157-173 

Blue & white 

174-189 

Red, green & blue 

190-206 

Red, green & white 

207-222 

Red, blue & white 

223-239 

Green, blue & white 

240-255 

Red, green, blue & white 

000-255 

Second head, Y axis position 

000-255 

Second head colour select 

000-255 

Third head, Y axis position 

000-255 

Third head colour select 

000-255 

Fourth head, Y axis position 

10 

000-255 

Fourth head colour select 

11 

000-255 

Fifth head, Y axis position 

10 

12 

000-255 

Fifth head colour select 

11 

13 

000-255 

Sixth head, Y axis position 

12 

14 

000-255 

Sixth head colour select 

Summary of Contents for VECTOR6

Page 1: ...le Bedfordshire United Kingdom LU6 3EJ Telephone 44 0 1582 690600 Fax 44 0 1582 690400 Email mail lambaplc com Web www lambaplc com If this product is ever no longer functional please take it to a rec...

Page 2: ...The lightning flash symbol inside a triangle is to alert the user to the presence high voltage within the unit s enclosure that may be of sufficient power to constitute a risk of electrical shock to...

Page 3: ...ad rigging required extensive experience Working load limits should be respected certified installation materials should be used the installed unit should be inspected regularly for safety l Make sure...

Page 4: ...LED Function menu...

Page 5: ...the Menu button to return to the main menu or wait 10 seconds and this will happen automatically 7 LED display setting Led Select Led in the Function Menu and press the Enter button to confirm Using t...

Page 6: ...mode 9 Press the Enter button to confirm your choice All unit should now operate in Master Slave mode where all units operate the same show as the first unit in the chain If you are only joining two u...

Page 7: ...73 Blue white 174 189 Red green blue 190 206 Red green white 207 222 Red blue white 223 239 Green blue white 240 255 Red green blue white 3 5 000 255 Second head Y axis position 4 6 000 255 Second hea...

Page 8: ...00 255 First head Y axis fine position 5 000 255 First head speed fast to slow 6 000 255 First head colour 7 000 255 Second head Y axis position 8 000 255 Second head Y axis fine position 9 000 255 Se...

Reviews: