AC power 

The unit is supplied with a power plug appropriate to its voltage. Should any other connections be required they must be carried 
out with the following configuration: 
 

Cable (EU) 

Cable (US) 

Pin 

International 

Brown 

Black 

Live 

Light blue

 

White 

Neutral 

Yellow/green 

Green 

Earth 

 

 
 
 

DMX-512 connection 

If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first 
unit in a DMX chain. If you wish to connect a DMX controller with other XLR outputs you will need to use adapter cables. 
 

       

1 = ground      2 = minus signal (-)     3 = plus signal (+) 

 

Connect the DMX output of the first unit in a DMX chain with the DMX input of the next unit in the chain. Always connect the the 
output of one unit with the input of the next unit until all units are connected. If you use a controller with 5 pin DMX connection you 
will need to use a 5 pin to 3 pin adapter.

 

 
 

 
Overhead rigging 
Important

 - the installation must be carried out by qualified service personal only. Improper installation can result in serious 

injuries and /or damage to property. Overhead rigging required extensive experience. Working load limits should be respected, 
certified installation materials should be used, the installed unit should be inspected regularly for safety. 

l

 

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing. 

l

 

Locate the unit in a well ventilated spot, far away from any flammable materials and/or liquids. The fixture must be fixed

 at 

least 50cm

 from surrounding walls 

l

 

The device should be installed out of reach of people and outside of areas where persons may walk by or be seated. 

l

 

Before rigging make sure that the installation area can hold minimum point load of 10 times the device’s weight. 

l

 

The device should be well fixed; a free swinging mounting is dangerous. 

l

 

Do not cover any ventilation opening as this may result in overheating 

Before first time use, the unit should be inspected for safety. Inspection the unit regularly every year. 
 
 
 

Quick Start Guide 

After connecting your unit to the mains, use the Function menu on the side panel of the unit to set the operating mode. 
Use the MENU button to make a function selection, then press ENTER to confirm it. Next use the UP and DOWN arrow buttons 
to refine your selection, then use the ENTER button to confirm your setting. 

 

 
 
 
 
 

 
 
 
 
 
 

Summary of Contents for VECTOR6

Page 1: ...le Bedfordshire United Kingdom LU6 3EJ Telephone 44 0 1582 690600 Fax 44 0 1582 690400 Email mail lambaplc com Web www lambaplc com If this product is ever no longer functional please take it to a rec...

Page 2: ...The lightning flash symbol inside a triangle is to alert the user to the presence high voltage within the unit s enclosure that may be of sufficient power to constitute a risk of electrical shock to...

Page 3: ...ad rigging required extensive experience Working load limits should be respected certified installation materials should be used the installed unit should be inspected regularly for safety l Make sure...

Page 4: ...LED Function menu...

Page 5: ...the Menu button to return to the main menu or wait 10 seconds and this will happen automatically 7 LED display setting Led Select Led in the Function Menu and press the Enter button to confirm Using t...

Page 6: ...mode 9 Press the Enter button to confirm your choice All unit should now operate in Master Slave mode where all units operate the same show as the first unit in the chain If you are only joining two u...

Page 7: ...73 Blue white 174 189 Red green blue 190 206 Red green white 207 222 Red blue white 223 239 Green blue white 240 255 Red green blue white 3 5 000 255 Second head Y axis position 4 6 000 255 Second hea...

Page 8: ...00 255 First head Y axis fine position 5 000 255 First head speed fast to slow 6 000 255 First head colour 7 000 255 Second head Y axis position 8 000 255 Second head Y axis fine position 9 000 255 Se...

Reviews: