Channel mode

 - choose A001 as the default address code. 

 

1. DMX512 address setting (Addr) 

Select 

Addr

 in the Function Menu and press the 

Enter

 button to confirm. Using the 

Up/Down

 buttons, select your initial address 

and press the 

Enter

 button to confirm. Press the 

Menu

 button to return to the main menu or wait 10 seconds and this will happen 

automatically. 
 

2. Channel mode (Chnd) 

Select 

Chnd

 in the Function Menu and press the 

Enter

 button to confirm. Using the 

Up/Down

 buttons, select a channel (e.g. 

6Ch 

which is 6 channel mode) and press the 

Enter

 button to confirm your choice (6, 12, 14 or 27). Press the 

Menu

 button to return to 

the main menu or wait 10 seconds and this will happen automatically. 
 

3. Master/Slave mode (SLnd) 

Select 

SLnd

 in the Function Menu and press the 

Enter

 button to choose between 

NASt

 (Master mode) or

 SL1

 (Slave 1 mode) or 

SL2

 (Slave 2 mode). Press the 

Enter

 button to confirm your choice. Press the 

Menu

 button to return to the main menu or wait 10 

seconds and this will happen automatically. 

 
4. Show mode (Shnd) 

Select 

Shnd

 in the Function Menu and press the 

Enter

 button to confirm. Using the 

Up/Down

 buttons, select a show (e.g. 

Sh0 - 

random show, 

Sh1

 - show 1, 

Sh2 

- show 2 and so on) and press the 

Enter

 button to confirm your choice. Press the 

Menu

 button 

to return to the main menu or wait 10 seconds and this will happen automatically. 
 

5. Sound-to-Light mode (SoUn) 

Select 

SoUn

 in the Function Menu and press the 

Enter

 button to confirm. Using the 

Up/Down

 buttons, select either 

ON 

or 

OFF 

and press the 

Enter

 button to confirm your choice. Press the 

Menu

 button to return to the main menu or wait 10 seconds and this 

will happen automatically. 

 

6. Sound-to-Light microphone sensitivity (SenS) 

Select 

SenS

 in the Function Menu and press the 

Enter

 button to confirm. Using the 

Up/Down

 buttons, select a microphone 

sensitivity setting (from 0-100)

 

and press the 

Enter

 button to confirm your choice. Press the 

Menu

 button to return to the main 

menu or wait 10 seconds and this will happen automatically. 

 

7. LED display setting (Led) 

Select 

Led

 in the Function Menu and press the 

Enter

 button to confirm. Using the 

Up/Down

 buttons, select either 

ON 

or 

OFF 

and press the 

Enter

 button to confirm your choice. Press the 

Menu

 button to return to the main menu or wait 10 seconds and this 

will happen automatically. 

 

8. LED display inversion (dISP) 

Select 

dISP

 in the Function Menu and press the 

Enter

 button to confirm. Choose either 

dISP

 which is the normal display setting 

or 

dSIP

 which rotates the display 180 degrees (inverts). Press the 

Menu

 button to return to the main menu or wait 10 seconds 

and this will happen automatically. 

 

9. Y axis position (tLtl) 

Select 

tLtl

 in the Function Menu and press the 

Enter

 button to confirm. Using the 

Up/Down

 buttons, select either 

NO 

(the first 

row, Y axis position) or 

YES 

(the first row, Y axis reverse position) after choosing press the 

Enter

 button to confirm your choice. 

Press the 

Menu

 button to return to the main menu or wait 10 seconds and this will happen automatically. 

 

10. Test mode (teSt) 

Select 

teSt

 in the Function Menu and press the 

Enter

 button to confirm. The LED display will flash and the unit will run a built-in 

self-test program. Press the 

Menu

 button to return to the main menu or wait 10 seconds and this will happen automatically. 

 

11. Working time (hour) 

Select 

hour

 in the Function Menu and press the 

Enter

 button to confirm. The LED display will show the working time of the unit. 

Press the 

Menu

 button to return to the main menu or wait 10 seconds and this will happen automatically. 

 

12. Software version (uer) 

Select 

uer

 in the Function Menu and press the 

Enter

 button to confirm. The LED display will show the software version. Press the 

Menu

 button to return to the main menu or wait 10 seconds and this will happen automatically. 

 

13. Auto-reset function (rSet) 

Select 

rSet

 in the Function Menu and press the 

Enter

 button to confirm. The unit will auto reset. Press the 

Menu

 button to return 

to the main menu or wait 10 seconds and this will happen automatically. 
 

Summary of Contents for VECTOR6

Page 1: ...le Bedfordshire United Kingdom LU6 3EJ Telephone 44 0 1582 690600 Fax 44 0 1582 690400 Email mail lambaplc com Web www lambaplc com If this product is ever no longer functional please take it to a rec...

Page 2: ...The lightning flash symbol inside a triangle is to alert the user to the presence high voltage within the unit s enclosure that may be of sufficient power to constitute a risk of electrical shock to...

Page 3: ...ad rigging required extensive experience Working load limits should be respected certified installation materials should be used the installed unit should be inspected regularly for safety l Make sure...

Page 4: ...LED Function menu...

Page 5: ...the Menu button to return to the main menu or wait 10 seconds and this will happen automatically 7 LED display setting Led Select Led in the Function Menu and press the Enter button to confirm Using t...

Page 6: ...mode 9 Press the Enter button to confirm your choice All unit should now operate in Master Slave mode where all units operate the same show as the first unit in the chain If you are only joining two u...

Page 7: ...73 Blue white 174 189 Red green blue 190 206 Red green white 207 222 Red blue white 223 239 Green blue white 240 255 Red green blue white 3 5 000 255 Second head Y axis position 4 6 000 255 Second hea...

Page 8: ...00 255 First head Y axis fine position 5 000 255 First head speed fast to slow 6 000 255 First head colour 7 000 255 Second head Y axis position 8 000 255 Second head Y axis fine position 9 000 255 Se...

Reviews: