background image

 

- 4 - 

 

1.

 

Recommendations 

In order the boiler served long and without troubles and you did not loose 

the right for guarantee service, please observe the following main rules: 

Attention:  It  is  strictly  prohibited  to  start  up  the  boiler  having  no  prior  filled 

boiler with thermal water. 

1.

 

Boiler  installation,  adjustment,  operator  training  can  be  performed  by  a 
firm,  attested  for  such  jobs  and  having  qualified  specialists  or  by 
representative authorized by manufacturer. Installation note has to be done 
in this certificate, installation report

2.

 

It is necessary to install the boiler into such heating system, which be able to 
maintain the return water temperature not less than 60 ºC. 

Attention:  If  you  fail  to  meet  this  requirement,  corrosion  will  occur  due  to 

condensate  which  will  significantly  reduce  service  life  of  the  body  and 
ceramic tiles.  

3.

 

Optimum operation of the boiler is achieved at close to nominal power. 

4.

 

If boiler power is too high and it has to be operated at lower than nominal 
power, we recommend to install the boiler with accumulation tank. 

5.

 

Use fuel no damper than 25 %. In the case of higher fuel dampness, boiler 
power drops, fuel consumption rises. 

6.

 

Having  the  heat  demand  lower  than  boiler  nominal  power,  in  order  to 
avoid  the  permanent  loaded  fuel  smoldering  (the  resins  may  start 
accumulating  inside  the  boiler),  do  not  load  the  furnace  in  full.    We 
recommend to load only one thirds of furnace.  

Note.

 

This operation manual is compiled following the requirements provided for 

in  EN  12171  Building  Heating  Systems.  Operation,  Maintenance  and  Use 
Document  Preparation  Procedures.  Heating  Systems  Needing  no  Trained 
Operator. 

2.

 

Intended use 

Solid  fuel  water  heating  boiler  "

Kalvis-2-70

"  (hereinafter 

referred  to  as  the 

“boiler”

) is used for heating of various premises where central heating system is 

installed with forced circulation and closed or open expansion system.  

The  boiler  operates  most  efficiently  under  nominal  taken  thermal  power,  

if  operating  with  lower  power,  the  accumulation  capacity  is  recommended  to  
use 

*

5 (

see page 5

)

Summary of Contents for K-2-70

Page 1: ...CENTRAL HEATING SOLID FUEL BOILER KALVIS 2 70 TECHNICAL CERTIFICATE INSTALLATION AND MAINTENANCE MANUAL Made in Lithuania Pagaminta Lietuvoje LST EN 303 5 2012 20548 87 20548 93...

Page 2: ...e 12 7 1 System preparation for heating 13 7 2 Boiler start up firing 13 7 3 Air draught regulator adjustment 14 7 4 Boiler firing 14 7 5 Boiler extinguishing 15 7 6 Boiler cleaning 15 7 7 Frequently...

Page 3: ...a variety of solid lump well dried fuel If desired the boiler is easy to adapt for stoking in mechanized way with pellets The boiler is manufactured using modern materials and technologies We believe...

Page 4: ...oiler power is too high and it has to be operated at lower than nominal power we recommend to install the boiler with accumulation tank 5 Use fuel no damper than 25 In the case of higher fuel dampness...

Page 5: ...than 40 Exhausted flue temperature at nominal output up to C 203 Exhausted flue quantity at nominal output kg s 0 058 Connection sockets dimensions flue channel mm 250 heating system in G2 B drainage...

Page 6: ...er front has air draught regulator 17 controlling the primary air supply valve 2 thermometer 16 pressure gauge 18 hearth service door 1 covering inner cast iron door 3 Fuel loading chamber is closed b...

Page 7: ...ntry In the extreme case wooden pallet can be used as fuel for the boiler Picture 2 Boiler packing for transportation 6 Boiler installation Boiler is to be installed in the premises meeting the releva...

Page 8: ...h extra elbow its cross section cannot be less than the cross section of fume escape from boiler hole with bending radius no less than 100 mm tube between the boiler flue and chimney shall be no longe...

Page 9: ...firemen make the openings in the chimney joint in a suitable place for periodical cleaning of soot once a month it is recommended to have boiler examined by qualified chimney expert once a year Notice...

Page 10: ...rming which ensures the long service life of the boiler not allows to form the condensate There are not shown the auxiliary technological equipment of the boiler house expansion vessel valves and othe...

Page 11: ...ary air supply dampers 27 see also chapter 7 3 6 5 Connection of the boiler cooling system According to the requirements of LST EN 303 5 standard par 4 1 5 11 3 for boiler operation it is necessary to...

Page 12: ...oling system Attention Emergency cooling coil cannot be used for hot water preparation 7 Boiler operate Boiler can be operated by adult persons well familiarized with boiler construction and this tech...

Page 13: ...ng the boiler from the system are not closed 7 2 Boiler start up firing Before starting the boiler open the smoke draught damper 15 see picture 1 ignition damper 13 through the doors 1 and 3 put crush...

Page 14: ...and add more fuel in the hearth Tightly close fuel loading door 6 and ignition damper 13 According to the selected temperature with the means of air draught adjuster 17 open the primary air supply va...

Page 15: ...ically aggressive acids under effect of which boiler service life can be reduced significantly In order to make sure that the boiler is tight stock it at high intensity for several hours then stop sto...

Page 16: ...oving fuel out of the boilers burning chamber put burning fuel to the utensil with water to get as little fume as possible accessing the premises open windows and doors Do not pour water into burning...

Page 17: ...is uninstalled due to other reasons Boiler is constructed from various materials so Bring electric appliances if present to electric appliances recycling organization Metal parts go to metal scrap Rem...

Page 18: ...moisture 35 40 Just cut tree contains 35 60 water Tree cut in the beginning of winter contains least quantity of water Hardwood contains less water Wood has to be cut and split to make firewood Firewo...

Page 19: ...or free Manufacturer takes no obligation for boiler operation and related consequences grants no warrant if the boiler is inadequately selected poorly installed see chapter 6 or operated see chapter 7...

Page 20: ...ress Telephone In the case of failure please call Company Address Telephone Manufacturer UAB Kalvis Pramon s 15 LT 78137 iauliai Lietuva Lithuania Telephone 370 671 88891 E mail prekyba kalvis lt Warr...

Page 21: ...nsions Diameter Height Length Chimney draught Number of elbows Last revision date Outgoing smoke temperature Brief description of boiler connection Fuel used for testing Type During boiler testing fun...

Page 22: ...ddress Experts Telephone Failure works carried out Repairs date Expert s signature Company Address Expert Telephone Failure works carried out Repairs date Expert s signature Company Address Expert Tel...

Page 23: ...manual requirements Regarding that I have claims for this product __________________________________________ I think that my upper listed deficiencies are defects of your product so please send your r...

Page 24: ...24 Stick product barcode here...

Reviews: