background image

41

GB

oiler

B

 

LCD

 

-

 

Stoves

 

Cod. 001121

Dear Customer,

We thank you for having chosen one of our products, the fruit of technological experience and of continual research for 
a superior quality product in terms of safety, dependability, and service.
In this manual you will find all the information and useful suggestions to use your product with the maximum safety 
and efficiency.

• Incorrect installation, incorrectly performed maintenance, improper use of the product release the manufacturer from 

every eventual damage derived from the use of the stove.

• The unit cannot be used as an incinerator. Do not use fuels other than pellets.
• This manual has been realized by the manufacturer and constitutes an integral part of the product and must remain 

with it during its entire lifetime. If the product is sold or transferred, be sure that the booklet is present since the 
information contained in it are addressed to the buyer, and to all those persons of various titles who complete the 
installation, use and maintenance.

• Carefully read the instructions and the technical information contained in this manual, before proceeding with the 

installation, use, and any operation on the product.

• The observance of the indications contained in the present manual guarantees the safety of people and the product, 

the economy of use and a longer functioning lifetime.

• Although the carefully studied design and the risk analysis done by our company has permitted the realization of a 

safe product, in any case, before effecting any operation on the stove, it is recommended to keep said manual avail-
able and pay scrupulous attention to the instructions written therein.

• Be very careful when moving the ceramic details where present.
• Check the precise flatness of the pavement where the product will be installed
• The wall where the product will be placed must not be constructed in wood, or in any case, made of an inflammable 

material, and in addition it is necessary to maintain a safety distance.

• While the stove is in operation, several parts of the stove (door, handle, sides) can reach high temperatures. Therefore 

pay attention and use the proper precautions, above all in the presence of children, elderly or disabled persons, and 
animals.

• Assembly must be performed by authorized persons (Authorized Assistance Center).
• Diagrams and drawings are furnished for the purpose of illustration; the manufacturer, with the intent of pursuing a 

policy of constant development and renewal of the product can, without any notice, make any modifications that are 
believed opportune.

•  When the stove is working at its maximum speed, it is strongly suggested to wear gloves while handling with the door 

for pellets loading and the door handle.

• It is prohibited to install in bedrooms or in explosive environments.
• Only use replacement parts recommended by the supplier.

In the event of a fire, disconnect the power supply, use an extinguisher and call the fire fighters if necessary. 
After that contact the Authorized Assistance Center.

Never cover the body of the stove in any way or obstruct the openings placed on the upper side 
when the device is operating. All our stoves are trial lighted on the construction line.

This instruction booklet is an integral part of the product: make sure that it always accompanies the appliance, even in 
case of transfer to another owner or in the case of transfer to another place.

 

In the event of damage or loss, request a 

copy from the area technician.

These symbols indicate specific messages in this booklet:

ATTENTION: 
This warning sign indicates that the message to which it refers should be carefully read and understood, 

because failure to comply with what these notices say can cause serious damage to the stove and 
put the user’s safety at risk.  

INFORMATION: 
This symbol is used to highlight information which is important for proper stove operation. Failure to 
comply with these provision will compromise use of the stove and its operation will not be satisfactory. 

We highly recommend to turn to our Authorized Service Centre for the installation and the first 
ignition of the device as it not only carries out the installation perfectly but also verifies the 
regular operation of it.

Summary of Contents for 24B

Page 1: ...USER MANUAL Ilaria Nadia 24B 24BDD Boiler Stoves Instructions for the correct use and maintenance of your Kalor wood pellet boiler stove Distribution and warranty in Ireland by...

Page 2: ...so offer a nationwide network of Authorised Technicians who are specially trained on Kalor wood pellet stoves This ensures that your stove can be correctly installed commissioned maintained and repair...

Page 3: ...s in operation several parts of the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled...

Page 4: ...for accidents deriving from the partial or total lack of observance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by...

Page 5: ...hlike must be kept a suitable distance from the stove Risk of fire Carefully explain that the thermostove is made from ma terial subjected to high temperatures for the elderly the disabled and in part...

Page 6: ...s prohibited The floor of the room where the thermostove is to be installed must be strong enough to take its weight If walls are flammable maintain a minimum distance of 10 cm at the rear A of 40 cm...

Page 7: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Page 8: ...be a wind proof type and must be above the ridge Eventual structures or other obstacles that are higher than the chimney cap must not be too close to the chimney cap itself Fig 5 Characteristics of c...

Page 9: ...LERANZE GENERALI DI LAVORAZIONE DIMENSIONI LINEARI 0 15 0 05 3 2 0 1 DIMENSIONI ANGOLARI PRECISIONE 12 GRADO DI FINO A 0 15 0 1 6 0 3 0 25 120 0 2 0 15 60 6 60 0 3 0 2 0 5 4000 0 8 0 6 1000 400 0 5 0...

Page 10: ...54 Pellet consumption min max Kg h 0 84 3 79 Heated surface mc 430 Flue gas flow rate min max g s 3 02 11 04 Draft min max Pa 3 8 Flue gas temperature min max C 51 1 103 Boiler water litri 31 Maximum...

Page 11: ...ly connected to the system and to allow slighht movement Diagram connection kit without hot water thermostove Plumbing system connection There are 2 different types of systems Closed vessel system Ope...

Page 12: ...3 bar the water used for filling the heating system must be decontaminated and without air When all the hydraulic connections are done proceed to test the pressure of the seals through the filling of...

Page 13: ...sed If you have very extensive system with a large amount of water or which require frequent refilling it is recommended the installation of water softening system It should be noted that the encrusta...

Page 14: ...termostato ext encoder ventilatore fumi encoder ventilatore fumi m 1 0 07 04 2017 P B C SCHEDA Q055 SCHEDA L023 LATO RISC Cn2 P2 P4 F P3 3VIE LATO SANIT N N TURBOLATORE OPZIONALE F PULITORE COMPATTAT...

Page 15: ...IZED TECHNICIAN How to select the type of Stand by OPERATION BY A SPECIALIZED TECHNICIAN Press the SET button press button to go to menu 09 Press the SET button again Enter the access key and confirm...

Page 16: ...adjust it with the e Reaction from the stand by state is when a heat increase is required to return to a chosen stand by condition when it is set to ON or when there is a health risk II I I Valve mot...

Page 17: ...AM 25 STAND BY IF PROBE H2O SET H2O a HEATING SANITARY HEALTH CALL ON 02 H2O WINTER ON IF H2O PARAM 25 MODULE IF PROBE H2O 80 C HEATING SANITARY SANITARIO NON CHIAMA OFF 03 TERM ES WINTER ON IF H2O PA...

Page 18: ...adjust it with the and keys The rinsing from the stand by state occurs automatically when a heat increase is required to return to satisfy the chosen stand by condition when this is set to ON or when...

Page 19: ...25 STAND BY IF PROBE H2O SET H2O a HEATING SANITARY HEALTH CALL ON 02 H2O WINTER ON IF H2O PARAM 25 MODULE IF PROBE H2O 80 C HEATING SANITARY SANITARIO NON CHIAMA OFF 03 TERM ES WINTER ON IF H2O PARA...

Page 20: ...adjust it with the and keys The rinsing from the stand by state occurs automatically when a heat increase is required to return to satisfy the chosen stand by condition when this is set to ON or when...

Reviews: