Fireplace flue gas

Avoid contact with combustible materials (example: 
wooden beams) and in any case provide for their insulation 
with flame retardant material. In case of pipe penetrations 
through roofs or walls is recommended to use special 
kits crossing, certificates, are available commercially. In 
the event of a chimney fire, turn off the stove, disconnect 
from the network and never open the door. Then call the 
authorities.

The chimney cap

The chimney cap must respect the following requirements: 
• It must have the equivalent diameter and internal form
of the flue. 
• It must have a useful outlet diameter of not less than 

double that of the flue. 

• The chimney cap on the roof or that remains in contact 

with the outside (for example, in case of open lofts or 
attics), must be covered with elements in brick or tile 
and must, in any case, be well insulated.

• It must be constructed to prevent rain, snow, and 

extraneous bodies from entering the flue and so that 
the discharge of the products of combustion is not 
inhibited by wind from any quarter or strength (wind-
proof chimney cap).

• The chimney cap must be positioned in such a way as 

to guarantee the adequate dispersion and dilution of the 
products of combustion and in any case, must be out of 
the reflux zone. This zone has different dimensions and 
forms according to the angle of inclination of the roof so 
it is necessary to adopt minimum heights (Fig. 2). 

• The chimney cap must be a wind-proof type and must 

be above the ridge.

•  Eventual structures or other obstacles that are higher 

than the chimney cap must not be too close to the 
chimney cap itself. 

Fig. 5: Characteristics of chimney

YES

NO

REMARKS:

- the appliance must be installed by a qualified technician in 
possession of the technical and professional requirements 
according to the DM37/2008 that, under its responsibility, 
to ensure compliance with the rules of good technique.
- the thermostove must be connected to a heating system 
and/or to a network of production of sanitary hot water, 
consistent with its performance and its power
- you need to keep in mind all laws and national, regional, 
provincial and municipal laws of the country in which you 
installed the device
- check that the floor is not flammable: if necessary use a 
suitable platform
- in the room where the generator must be installed to 
heat must not pre-exist or be installed with an extractor 
hood or ventilation ducts of the collective type.
Should these devices be located in adjacent rooms 
communicating with the installation, and ‘prohibited the 
simultaneous use of the heat generator, where there is a 
risk that one of the two rooms being placed in depression 
than the other
- it is not permissible to install in bedrooms or bathrooms
- for hydraulic connections (see next chapter) it is advisable 
to use where possible of hoses

Distance to objects

The thermostove should be inspected on all sides, so you 
have to keep a distance of at least 40 cm at the back and 
sides. It is also recommended to keep the pellets and all 
flammable materials at a suitable distance

40 cm

100 cm

40 cm

Summary of Contents for 24B

Page 1: ...USER MANUAL Ilaria Nadia 24B 24BDD Boiler Stoves Instructions for the correct use and maintenance of your Kalor wood pellet boiler stove Distribution and warranty in Ireland by...

Page 2: ...so offer a nationwide network of Authorised Technicians who are specially trained on Kalor wood pellet stoves This ensures that your stove can be correctly installed commissioned maintained and repair...

Page 3: ...s in operation several parts of the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled...

Page 4: ...for accidents deriving from the partial or total lack of observance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by...

Page 5: ...hlike must be kept a suitable distance from the stove Risk of fire Carefully explain that the thermostove is made from ma terial subjected to high temperatures for the elderly the disabled and in part...

Page 6: ...s prohibited The floor of the room where the thermostove is to be installed must be strong enough to take its weight If walls are flammable maintain a minimum distance of 10 cm at the rear A of 40 cm...

Page 7: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Page 8: ...be a wind proof type and must be above the ridge Eventual structures or other obstacles that are higher than the chimney cap must not be too close to the chimney cap itself Fig 5 Characteristics of c...

Page 9: ...LERANZE GENERALI DI LAVORAZIONE DIMENSIONI LINEARI 0 15 0 05 3 2 0 1 DIMENSIONI ANGOLARI PRECISIONE 12 GRADO DI FINO A 0 15 0 1 6 0 3 0 25 120 0 2 0 15 60 6 60 0 3 0 2 0 5 4000 0 8 0 6 1000 400 0 5 0...

Page 10: ...54 Pellet consumption min max Kg h 0 84 3 79 Heated surface mc 430 Flue gas flow rate min max g s 3 02 11 04 Draft min max Pa 3 8 Flue gas temperature min max C 51 1 103 Boiler water litri 31 Maximum...

Page 11: ...ly connected to the system and to allow slighht movement Diagram connection kit without hot water thermostove Plumbing system connection There are 2 different types of systems Closed vessel system Ope...

Page 12: ...3 bar the water used for filling the heating system must be decontaminated and without air When all the hydraulic connections are done proceed to test the pressure of the seals through the filling of...

Page 13: ...sed If you have very extensive system with a large amount of water or which require frequent refilling it is recommended the installation of water softening system It should be noted that the encrusta...

Page 14: ...termostato ext encoder ventilatore fumi encoder ventilatore fumi m 1 0 07 04 2017 P B C SCHEDA Q055 SCHEDA L023 LATO RISC Cn2 P2 P4 F P3 3VIE LATO SANIT N N TURBOLATORE OPZIONALE F PULITORE COMPATTAT...

Page 15: ...IZED TECHNICIAN How to select the type of Stand by OPERATION BY A SPECIALIZED TECHNICIAN Press the SET button press button to go to menu 09 Press the SET button again Enter the access key and confirm...

Page 16: ...adjust it with the e Reaction from the stand by state is when a heat increase is required to return to a chosen stand by condition when it is set to ON or when there is a health risk II I I Valve mot...

Page 17: ...AM 25 STAND BY IF PROBE H2O SET H2O a HEATING SANITARY HEALTH CALL ON 02 H2O WINTER ON IF H2O PARAM 25 MODULE IF PROBE H2O 80 C HEATING SANITARY SANITARIO NON CHIAMA OFF 03 TERM ES WINTER ON IF H2O PA...

Page 18: ...adjust it with the and keys The rinsing from the stand by state occurs automatically when a heat increase is required to return to satisfy the chosen stand by condition when this is set to ON or when...

Page 19: ...25 STAND BY IF PROBE H2O SET H2O a HEATING SANITARY HEALTH CALL ON 02 H2O WINTER ON IF H2O PARAM 25 MODULE IF PROBE H2O 80 C HEATING SANITARY SANITARIO NON CHIAMA OFF 03 TERM ES WINTER ON IF H2O PARA...

Page 20: ...adjust it with the and keys The rinsing from the stand by state occurs automatically when a heat increase is required to return to satisfy the chosen stand by condition when this is set to ON or when...

Reviews: