Kalor 24B User Manual Download Page 4

42

GB

Our company declares that the stove conforms to the fol-
lowing norms for the EC European Directive labelling:
• 

2014/30 UE (regulation EMCD) and following 

 

amendments;

• 2014/35 UE (Low Voltage Directive) and following 

amendments;

• 2011/65 UE (RoHS 2 directive);
• The New Rules of Construction Products (CPR-Con-

struction Products Regulation) No. 305/2011 regarding 
the construction world;

• For installations in Italy, please refer to UNI 10683/98 or 

following changes. For the water-thermo-sanitary equip-
ment, let the installer give you the conformity declaration 
in compliance with L. 37/2008. While installing the unit 
respect the local, national and Europen rules;

• EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3; 

EN 60335-1; EN 60335-2-102; EN 62233, EN 50581.

Safety information

Please carefully read this use and maintenance manual 
before installing and operating the stove! 
If clarification is needed, please contact the dealer or the 
Authorized Assistance Center.
• The pellet stove must only be operated in living envi-

ronments. This stove, being controlled by an electronic 
board, permits a completely automatic and controlled 
combustion; the exchange, in fact, regulates the lighting 
phase, 5 power levels and the shut down stage, guaran-
teeing the safe operation of the stove.

• The basket used for combustion allows most of the ash 

produced by the combustion of the pellets to fall into 
the collection compartment. Nevertheless, check the 
basket daily, given that not all pellets have high qual-
ity standards (use only quality pellets recommended by 
the manufacturer).

Responsibility

With the delivery of the present manual, we decline all 
responsibility, both civil and penal, for accidents deriving 
from the partial or total lack of observance of the instruc-
tions contained herein.
We decline every responsibility derived from improper 
use of the stove, from incorrect use by the user, from un-
authorized modifications and/or repairs, from the use of 
replacement parts that are not original for this model.
The manufacturer declines every civil or penal, direct or 
indirect responsibility due to:
• Lack of maintenance;
• Failure to observe the instructions contained in the 

manual;

• Use in non-conformity with the safety directives;
• Installation in non-conformity with the norms in force in 

the country;

• Installation by unqualified or untrained personnel;
• Modifications and repairs not authorized by the 

manufacturer;

• Use of non-original replacement parts;
• Exceptional events.

Norms and declarations of conformity

• Use only wood pellets;
•Keep / store the pellets in a cool dry 

place;

• Never pour pellets directly on the hearth;
• The thermostove must only be fed with quality 

6 mm diameter pellets of the type recommend-
ed by the manufacturer;

• Before making the electrical connection of the 

thermostove the discharge tubes must be con-
nected with the flue;

• The protective grill placed inside the pellet con-

tainer must never be removed;

• The environment where the stove is installed 

must have a sufficient exchange of air;

• It is forbidden to operate the thermostove with 

the door open or the glass broken;

• Do not use the thermostove as an incinerator; 

the thermostove should be used only for the in-
tended purpose;

• Any other use is considered improper and 

therefore dangerous. Do not put in the hopper 
other than wood pellets;

• When the thermostove is operating, the surfac-

es, glass, handle and tubes become very hot: 
during operation do not touch these parts with-
out adequate protection;

• Keep the fuel and other inflammable materials 

off the thermostove.

Summary of Contents for 24B

Page 1: ...USER MANUAL Ilaria Nadia 24B 24BDD Boiler Stoves Instructions for the correct use and maintenance of your Kalor wood pellet boiler stove Distribution and warranty in Ireland by...

Page 2: ...so offer a nationwide network of Authorised Technicians who are specially trained on Kalor wood pellet stoves This ensures that your stove can be correctly installed commissioned maintained and repair...

Page 3: ...s in operation several parts of the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled...

Page 4: ...for accidents deriving from the partial or total lack of observance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by...

Page 5: ...hlike must be kept a suitable distance from the stove Risk of fire Carefully explain that the thermostove is made from ma terial subjected to high temperatures for the elderly the disabled and in part...

Page 6: ...s prohibited The floor of the room where the thermostove is to be installed must be strong enough to take its weight If walls are flammable maintain a minimum distance of 10 cm at the rear A of 40 cm...

Page 7: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Page 8: ...be a wind proof type and must be above the ridge Eventual structures or other obstacles that are higher than the chimney cap must not be too close to the chimney cap itself Fig 5 Characteristics of c...

Page 9: ...LERANZE GENERALI DI LAVORAZIONE DIMENSIONI LINEARI 0 15 0 05 3 2 0 1 DIMENSIONI ANGOLARI PRECISIONE 12 GRADO DI FINO A 0 15 0 1 6 0 3 0 25 120 0 2 0 15 60 6 60 0 3 0 2 0 5 4000 0 8 0 6 1000 400 0 5 0...

Page 10: ...54 Pellet consumption min max Kg h 0 84 3 79 Heated surface mc 430 Flue gas flow rate min max g s 3 02 11 04 Draft min max Pa 3 8 Flue gas temperature min max C 51 1 103 Boiler water litri 31 Maximum...

Page 11: ...ly connected to the system and to allow slighht movement Diagram connection kit without hot water thermostove Plumbing system connection There are 2 different types of systems Closed vessel system Ope...

Page 12: ...3 bar the water used for filling the heating system must be decontaminated and without air When all the hydraulic connections are done proceed to test the pressure of the seals through the filling of...

Page 13: ...sed If you have very extensive system with a large amount of water or which require frequent refilling it is recommended the installation of water softening system It should be noted that the encrusta...

Page 14: ...termostato ext encoder ventilatore fumi encoder ventilatore fumi m 1 0 07 04 2017 P B C SCHEDA Q055 SCHEDA L023 LATO RISC Cn2 P2 P4 F P3 3VIE LATO SANIT N N TURBOLATORE OPZIONALE F PULITORE COMPATTAT...

Page 15: ...IZED TECHNICIAN How to select the type of Stand by OPERATION BY A SPECIALIZED TECHNICIAN Press the SET button press button to go to menu 09 Press the SET button again Enter the access key and confirm...

Page 16: ...adjust it with the e Reaction from the stand by state is when a heat increase is required to return to a chosen stand by condition when it is set to ON or when there is a health risk II I I Valve mot...

Page 17: ...AM 25 STAND BY IF PROBE H2O SET H2O a HEATING SANITARY HEALTH CALL ON 02 H2O WINTER ON IF H2O PARAM 25 MODULE IF PROBE H2O 80 C HEATING SANITARY SANITARIO NON CHIAMA OFF 03 TERM ES WINTER ON IF H2O PA...

Page 18: ...adjust it with the and keys The rinsing from the stand by state occurs automatically when a heat increase is required to return to satisfy the chosen stand by condition when this is set to ON or when...

Page 19: ...25 STAND BY IF PROBE H2O SET H2O a HEATING SANITARY HEALTH CALL ON 02 H2O WINTER ON IF H2O PARAM 25 MODULE IF PROBE H2O 80 C HEATING SANITARY SANITARIO NON CHIAMA OFF 03 TERM ES WINTER ON IF H2O PARA...

Page 20: ...adjust it with the and keys The rinsing from the stand by state occurs automatically when a heat increase is required to return to satisfy the chosen stand by condition when this is set to ON or when...

Reviews: