6. Hot Temperature Adjustment (continued)
Insert a thermometer into the water stream to verify the water
temperature.
Turn the valve stem clockwise until the maximum 120°F (49°C)
temperature is reached.
Reinstall the valve spline adapter over the valve stem. Ensure the
adapter tab placed flush against the left side of the hot tab on the
cartridge.
Shut off the volume control (not shown), then turn both integral
supply stops outward until they contact the stop bracket.
Open and close the volume control (not shown) to relieve
pressure that has built up in the valve.
Remove the head nut from the assembly by turning the head nut
counterclockwise.
Reinstall the detent collar. Be sure the spring is resting on top of
the detent collar.
Reinstall the head nut onto the assembly until hand-tight. Do not
overtighten.
Reattach the removal clip to the head nut. The tab on the removal
clip should be facing inward.
Turn both integral supply stops inward.
Verify the temperature. Repeat the
″
Hot Temperature Adjustment
procedure, if necessary.
Head Nut
Removal Clip
Removal
Clip Tab
Detent Collar
with Spring
Valve Spline
Adapter
Integral
Supply Stop
Stop Bracket
Integral Supply Stop
Valve Stem
Adapter Tab
Hot
Tab
1048326-2-B
16
Kallista