7. Shower Temperature Adjustment
NOTE:
To ensure the correct shower temperature, first turn the
valve spline adapter to the full hot position then adjust the shower
temperature.
Place the trim handle (not shown) or plaster guard (not shown)
onto the valve spline adapter.
Turn the valve spline adapter fully counterclockwise so the trim
handle or plaster guard can no longer move. The valve spline
adapter is now in the full hot position.
Turn the trim handle or plaster guard clockwise until you hear a
″
click.
″
Do not turn any farther. This is the shower temperature
position.
NOTE:
If a
″
click
″
is not heard or felt, detach the trim handle. Pull
out and rotate the detent collar 180° until it snaps back into place.
Reattach the trim handle and repeat the steps above to find the
shower temperature position.
Remove the trim handle or plaster guard from the valve spline
adapter.
Allow the water to run for a few minutes to stabilize the
temperature.
Hold a thermometer in the water stream to check the water
temperature.
If the temperature is less than 104°F (40°C):
Detent Collar
Valve Spline Adapter
Increase
temperature.
Decrease
temperature.
Kallista
17
1048326-2-B