Thermometer
This valve meets or exceeds ANSI
A112.18.1/CSA B125.1/ASSE 1016.
Observe all local plumbing and
building codes.
Record your model number below
for future reference:
CAUTION: Risk of product
damage:
Use only silicone
based lubricants with this product.
Other lubricants may cause damage.
WARNING: Risk of scalding.
This valve will not protect
against scalding if incoming water
temperature changes significantly
during operation.
WARNING: Risk of scalding.
High water temperature can
cause severe burns. Set the water
temperature at or below 120°F
(49°C) following the adjustment
procedure in this document.
Aspirator
To reverse the aspirator, push it out
with a screwdriver and reinstall in the
opposite port.
Aspirator
4
Confirm the aspirator is aligned
with the showerhead outlet.
Reverse the aspirator if needed.
3
Align the “COLD” mark with the
cold water supply.
O-Ring
2
Confirm the O-rings are
undamaged and properly seated
around each port and the base.
1
Turn off the water supply to the
valve. If the test cap is installed,
remove it now.
Stop
8
Temperature Adjustment:
Remove the plaster guard or trim
(not shown) if installed. Remove
the warning tag and stop.
7
Measure the maximum water
temperature. If the water is too
hot or cold, adjustment is
required.
WARNING: Risk of scalding.
Do not set the water
temperature above 120°F (49°C).
6
Turn on the water supply. Turn
the valve stem clockwise to the
full hot position.
5
Install the cartridge with the
“COLD” port aligned with the cold
supply.
Reinstall the warning tag. If the
finished wall is not installed reinstall
the plaster guard (not shown).
Turn off the valve using the plaster
guard.
If finer adjustment is needed, reverse
the stop.
Tab
With the water still on, reinstall the
stop against the tab.
Turn on the water. Adjust the valve
stem until the desired maximum
temperature is found.
1260141-2-
B