INSTALLATION INSTRUCTIONS

Handshower, Hose 

& Handshower Accessories 

1188577-2-F

Questions? Problems? For additional assistance, please contact KALLISTA’s Customer

Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com

1 of 5

P21650, P21660, P24452, P24453, 
P24454, P24456, P24743, P24745, 

P24746, P24761, P24843

©2014 KALLISTA

Summary of Contents for P21650

Page 1: ...es 1188577 2 F Questions Problems For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or kallista com 1 of 5 P21650 P21660 P24452 P24453...

Page 2: ...ws the water temperature to become too hot when other plumbing products are used Prior to using your shower verify your new showerhead handshower is compatible with your shower valve located behind th...

Page 3: ...Install a temporary nipple into the shower ell Run water through the system to flush out dirt and debris Remove the temporary nipple from the shower ell Apply several layers of sealant tape around the...

Page 4: ...hors Drill the holes and install the wall anchors Attach the fixed wall bracket to the wall with the screws 3 INSTALL THE HANDSHOWER AND HOSE Handshower Washer Fixed Wall Bracket Handshower Connector...

Page 5: ...Coupling Tube Handshower Bracket Drill a 5 16 hole for the anchor Determine the location for the slidebar Mark the hole locations for the wall anchors Drill the holes and install the wall anchors Att...

Page 6: ...ated Supply Elbow 1230883 2 B 1 of 3 Questions Problems For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or kallista com Wall Bracket...

Page 7: ...r listed at the bottom of the page BEFORE YOU BEGIN NOTE Plumbing codes may require a vacuum breaker be installed in line to handshowers Please consult with local plumbing codes Carefully plan the loc...

Page 8: ...T nipple Install the nipple to extend 11 16 17 mm beyond the finished wall Ensure the gap between the nipple and finished wall is no more than 3 8 10 mm 2 INSTALL THE WALL BRACKET Outlet Wall Bracket...

Page 9: ...TIONS Shower Arms 1193441 2 A 1 of 3 Questions Problems For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or FAX 1 888 272 3094 P21520...

Page 10: ...l your KALLISTA product If you encounter any installation or performance problems please do not hesitate to contact us at the phone number listed at the bottom of the page IMPORTANT IMFORMATION Observ...

Page 11: ...thread sealant tape on the shower arm threads Do not use thread sealant compound pipe dope NOTE The showerhead and escutcheon are not provided Remove the temporary nipple from the shower ell Slide the...

Page 12: ...TIONS Shower Arms 1193441 2 A 1 of 3 Questions Problems For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or FAX 1 888 272 3094 P21520...

Page 13: ...l your KALLISTA product If you encounter any installation or performance problems please do not hesitate to contact us at the phone number listed at the bottom of the page IMPORTANT IMFORMATION Observ...

Page 14: ...thread sealant tape on the shower arm threads Do not use thread sealant compound pipe dope NOTE The showerhead and escutcheon are not provided Remove the temporary nipple from the shower ell Slide the...

Page 15: ...adapter 3 Temporarily fit the valve stem adapter on the spline adapter 2 Remove the plaster guard Place the spline adapter on the valve stem 1 1 16 27 mm 1 9 16 40 mm Thick Wall Use the 2 adapter and...

Page 16: ...your Kallista Authorized Showroom IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY KALLISTA...

Page 17: ...Installation Guide Three Way Transfer Valve P29513 P29514 1091987 2 B...

Page 18: ...nsfer valve until instructed to do so A mixed water supply is required for this transfer valve Do not plug any outlets on this transfer valve The transfer valve is not intended to be used as a shut of...

Page 19: ...Begin cont Inspect the waste and supply tubing replace if necessary KALLISTA reserves the right to make revisions in the design of products without notice as specified in the Price Book Kallista 3 10...

Page 20: ...the Water Supply Route the 3 4 mixed water supply line to the transfer valve location Apply thread sealant to the inlet port threads and connect the water supply to the transfer valve inlet Plaster Gu...

Page 21: ...ping and outlet ells to the framing Install temporary 1 2 nipples in the outlet ells so they extend a minimum of 2 51 mm beyond the planned finished wall Turn on the water supply to the transfer valve...

Page 22: ...eck the transfer valve for proper operation and leakage Once everything is verified turn off the water Install caps on the temporary bath and shower nipples Turn on the water and check for leaks Once...

Page 23: ...1091987 2 B...

Page 24: ...USA Canada 1 888 4 KALLISTA Fax 1 888 272 3094 kallista com 2012 KALLISTA 1091987 2 B...

Page 25: ...fit the handle to confirm vertical alignment 6 Install the correct parts according to Y Verify level 5 Make sure the valve is closed Y 2 51 mm Y 1 3 4 44 mm 2 51 mm 1 5 8 41 mm 2 51 mm 4 Use parts acc...

Page 26: ...Questions Problems For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or kallista com 1286745 2 A 2016 KALLISTA...

Page 27: ...the COLD mark with the cold water supply O Ring 2 Confirm the O rings are undamaged and properly seated around each port and the base 1 Turn off the water supply to the valve If the test cap is insta...

Page 28: ...ons provided by Kallista Improper care or cleaning including damage from the use of abrasive chemicals will void this warranty Gloss reduction scratching staining and alkaline etching of finishes over...