Kalfire W Series Installation And User Manual Download Page 37

Tips

 

  Use enough wood to ignite the Kalfire:

  -  Kalfire W45/48F 

ca. 2 kg

  -  Kalfire W70/33F 

ca. 3 kg

  -   Kalfire W60/51F, W85/40F, W65/38C,  

W66/48S, W90/47C, W90/47S 

ca. 4 kg

  -   Kalfire W71/62F, W100/61F, W105/47F,  

W80/52T en W105/47T 

ca. 6 kg

 

   When the fire has been lit, leave the door slightly open (1-2 

cm) for a few minutes; the wood will catch fire more easily 
and the flue will be quickly warmed-up.

 

Do not use white spirits, petrol, oil or other liquid fuels.

Be aware that weather conditions (air pressure, temperature, 
wind) can influence combustion. Minimize these influences by 
adjusting the secondary air supply.

5.6  Optimal heat output

For optimal heat production we advise you to burn wood 
according to the instructions below. This will achieve the same 
performance and emission values, obtained during inspection of 
the appliances.
 

  Ensure a glowing bed is created (see section 5.5).

 

   Use logs of wood of approximately the same size. The 

amount differs per Kalfire W model. See table below.

Table 6 Instructions for optimal burning per model

* Weight for beech wood. 

Kalfire model

W45/48F

W60/51F

W65/38C

W66/48S

W70/33F

W71/62F

W80/52T

Weight* per log (g)

850

850

950

975

800

1100

850

Number of logs

2

3

3

3

3

3

4

Max. weight* wood per hour (kg)

2.3

3.6

4

3.5

2.9

5

4.5

Air regulation open (%)

100

50

30

25

75

33

90

Kalfire model

W85/40F

W90/47C

W90/47S

W100/61F

W105/47F

W105/47T

W120/38F

Weight* per log (g)

1000

850

1400

1200

1280

1100

1300

Number of logs

3

4

3

3

3

4

3

Max. weight* wood per hour (kg)

4

4

5.5

3.6

4.6

5

5.2

Air regulation open (%)

50

10

50

60

33

50

100

37

Summary of Contents for W Series

Page 1: ...Installation and user manual CLOSED WOOD FIRES DON T COMPROMISE EN...

Page 2: ......

Page 3: ...en and closed Models Kalfire W45 48F Kalfire W60 51F Kalfire W65 38C Kalfire W66 48S Kalfire W70 33F Kalfire W71 62F Kalfire W80 52T Kalfire W85 40F Kalfire W90 47C Kalfire W90 47S Kalfire W100 61F Ka...

Page 4: ...4...

Page 5: ...lier cannot be held responsible for any damage because of faulty installation In case any problems occur or if you have any questions concerning the operation of your fireplace please contact your Kal...

Page 6: ...6...

Page 7: ...2 Check flue 14 3 3 Placing the appliance 14 3 3 1 Working combustion air 15 3 4 Supply of combustion air 16 3 4 1 Fresh air connection base or rear 16 3 4 2 Fresh air connection without connecting co...

Page 8: ...fire W60 51F Kalfire W65 38C Kalfire W66 48S Kalfire W70 33F Kalfire W71 62F Kalfire W80 52T Kalfire W85 40F Kalfire W90 47C Kalfire W90 47S Kalfire W100 61F Kalfire W105 47F Kalfire W105 47T Kalfire...

Page 9: ...nt overheating of floor boards or walls close to the fireplace 2 3 Safety instructions user The Kalfire wood fire is only intended for use as an additional heat source Careful The exterior of the fire...

Page 10: ...ase cm Rear panel cm Side panel cm Roof cm Base cm Rear panel cm Side panel cm Roof cm Base cm Rear panel cm Side panel cm Roof cm Base cm W45 48F 5 5 9 2 6 2 7 5 3 2 0 2 1 4 1 5 5 9 W60 51F 5 5 9 2 6...

Page 11: ...t be protected to a distance of at least 50 cm in front of the appliance side sides with a glass door 2 4 3 Installation of the Kalfire W90 47C in combination with combustible materials e g a wooden w...

Page 12: ...struction and heat insulation in order to considerably reduce the built in depth Cover heat insulating materials made from stone and clinker fibre so they are not subject to wear otherwise loose parti...

Page 13: ...the supplier immediately 2 Remove the transport security screws with yellow sticker on the front of the convection casing 3 Check the following parts for correct working Lifting door up and down Forwa...

Page 14: ...r pressure that remains below 0 04 mbar ATTENTION This situation must also be safeguarded if easily accessible control equipment used for the ventilating installation is moved or removed a supply of f...

Page 15: ...he air flow is regulated manually via the operating feature to the right of the appliance Via risers to the left and right of the combustion chamber this air is warmed up and guided to the combustion...

Page 16: ...lar 150 mm 3 4 Supply of combustion air The appliance must have enough outside air to ensure problem free ignition If lower values are established based on the calculated volume of combustion air buil...

Page 17: ...sure area the same room as the fireplace Kalfire W90 47S Two flexible aluminium hoses 150 mm 1 25 m one hose of 2 5 m that is divided into two hoses Four hose brackets Two grills outer dimensions 20 c...

Page 18: ...this type of combined installation in order to comply with fire regulations In heat storage radiation installations the convection hood should remain mounted on the Kalfire W The maximum wood amount i...

Page 19: ...150 mm 150 W60 51F 545 470 2560 1 150 mm 180 W65 38C 610 374 333 374 3527 2 150 mm 180 200 W66 48S 355 475 2 620 475 4631 2 150 mm 200 W70 33F 305 665 2028 2 150 mm 180 W71 62F 655 580 3800 2 150 mm 2...

Page 20: ...Use the Kalfire stainless steel insulated flue duct for this purpose Kalfire advises you not to use larger flue diameters than the connection present on the appliance Using a larger flue diameter can...

Page 21: ...nvection casing 2 The connection piece is now visible and the four bolts can be unscrewed 3 Turn the connecting piece 180 4 Press the punched cover out of the convection casing this cover is used to c...

Page 22: ...flue duct is only possible with a chimney duct of minimum 4 5 metres and maximum 6 metres long Figure 2 Reducer ring 3 7 Mounting the damper The Kalfire W is delivered as standard without a damper A d...

Page 23: ...to place the two bolts back Kalfire W corner and 3 sided models Fine adjustment Screw the bolt at the adjustment foot to set the precise height Range 3 cm Use this method to set the fireplace perfect...

Page 24: ...any plastic substances High temperatures may cause plastic to discolour 6 Before completely closing off the surround ensure that the inside of the surround is clean and free of dust Preferably use a...

Page 25: ...be necessary to remove the baffle plate completely Kalfire W70 33F W105 47F and W120 38F The Kalfire W70 33F W105 457F and W120 38F have a removable baffle plate This baffle plate is situated above th...

Page 26: ...bracket A maximum of 6 cm can be removed from the baffle plate All baffle plates must be removed if the Kalfire W60 51F W71 62F or W85 40F is used as an open fire place Kalfire W100 61F The Kalfire W1...

Page 27: ...S W90 47C and W90 47S are used as an open fireplace some smoke may flow back into the room even if both baffle plates have been removed This may have a number of causes Insufficient pull in the chimne...

Page 28: ...3 10 Finish Finish upper side Kalfire W66 48S and W90 47S The surround above the Kalfire W66 48S and W90 47S must have at least 2 mm of play in relation to the trim above the door 28...

Page 29: ...10 3 12 7 15 8 13 2 Heat output 86 81 82 80 80 83 80 81 Energy efficiency class A A A A A A A A Energy efficiency Index 115 108 109 106 106 110 106 108 Flue gas temperature C 270 260 257 247 282 302...

Page 30: ...4 CO at 13 O2 0 1 0 1 0 09 0 08 0 10 0 11 CO2 content 8 6 9 9 8 8 9 46 7 4 8 6 Dust content at 13 O2 mg nm 20 30 22 11 25 44 NOx at 13 O2 mg nm 138 112 116 118 150 104 CnHm at 13 O2 mg nm 93 78 90 60...

Page 31: ...broadleaf wood with hardwood This will benefit the lifespan of the Kalfire W and will create a more attractive play of flames 4 2 Storing the wood All types of wood should be stored for about 2 to 3 y...

Page 32: ...en heated the enamel is soft and will stick sooner If the door does stick to the fireplace it can be tilted see section 5 2 5 2 Opening the door The Kalfire W is equipped with a lifting door To open t...

Page 33: ...ain difference is that each use has a different air requirement For this reason the Kalfire W features a fresh air valve at the rear of the appliance patent Advantage The air required by the flue duct...

Page 34: ...ear wall Place a smaller log on top Place some firelighters on top Place some finely chopped wood onto the logs Open the air regulation completely position on the extreme right Ignite the firelighters...

Page 35: ...lace two pieces diagonally on top Place some firelighters on the logs Place some finely chopped wood onto the logs Open the air regulation completely position on the extreme right Ignite the firelight...

Page 36: ...s using a long match Leave the door slightly open 1 2 cm for a couple of minutes Place 2 logs diagonally on top of the wood together with a few firelighters Use the operating key to open the air regul...

Page 37: ...wood according to the instructions below This will achieve the same performance and emission values obtained during inspection of the appliances Ensure a glowing bed is created see section 5 5 Use lo...

Page 38: ...both as an open or closed fireplace Remove both baffle plates before using the appliance with the door open to enable correct exhaust of the flue gas Kalfire W60 51F Three logs are approx 25 cm long...

Page 39: ...ree logs are approx 32cm long for the Kalfire W105 47F Kalfire W100 61F and W120 38F Position the logs in an A shape with the horizontal log at the top The three logs are approx 29 cm long Kalfire W66...

Page 40: ...sition the logs in an A shape with the horizontal log at the base Kalfire W80 52T and W105 47T Place 4 logs of approx ca 30cm long in a cross shape in the centre of the fireplace When the logs have be...

Page 41: ...letely before opening the door When the wood is burning to your satisfaction you can partly close the damper again Open door use Kalfire W45 48F We advise you to keep the door of the Kalfire W45 48F d...

Page 42: ...ont of the fireplace will remain clean 6 Maintenance 6 1 Keeping clean panes To keep the panes clean Only burn dry wood with a moisture level of approximately 15 and stored dry and chopped for 2 years...

Page 43: ...d forward see image Take hold of the door on and gently pull it forward 6 Use a cloth or piece of paper to remove the worst soiling from the glass 7 Spray the detergent onto a cloth or piece of paper...

Page 44: ...and can be tilted forward Grasp the door by the glass or by the steel edge at the top and pull it forward carefully 5 Use a cloth or piece of paper to remove the worst soiling from the glass 6 Spray...

Page 45: ...ately Only use Kalfire spare parts as replacement parts if necessary These parts can be obtained from your trade dealer To close the door again tilt it back and turn the key to the right The fireplace...

Page 46: ...re bricks or skamol plates are broken Cracks in the inner housing do not influence the operation of the Kalfire Odour nuisance When the fireplace is used for the first time a chemical odour is release...

Page 47: ...8 020 2014 Kalfire W65 38C N P8 054 2015 Kalfire W66 48S N P8 8017 2015 Kalfire W70 38F N P8 025 2011 Kalfire W71 62F N P8 070 2015 Kalfire W80 52T N P8 001 2015 Kalfire W85 40F N P8 048 2010 Kalfire...

Page 48: ...APPENDIX B Dimension diagrams Kalfire W45 48F All dimensions shown in mm Dimensions subject to modification 48...

Page 49: ...Kalfire W60 51F All dimensions shown in mm Dimensions subject to modification 49...

Page 50: ...Kalfire W65 38CL All dimensions shown in mm Dimensions subject to modification 50...

Page 51: ...Kalfire W65 38CR All dimensions shown in mm Dimensions subject to modification 51...

Page 52: ...Kalfire W66 48S All dimensions shown in mm Dimensions subject to modification 52...

Page 53: ...Kalfire W70 33F All dimensions shown in mm Dimensions subject to modification 53...

Page 54: ...Kalfire W71 62F All dimensions shown in mm Dimensions subject to modification 54...

Page 55: ...Kalfire W80 52T All dimensions shown in mm Dimensions subject to modification 55...

Page 56: ...Kalfire W85 40F All dimensions shown in mm Dimensions subject to modification 56...

Page 57: ...Kalfire W90 47CL All dimensions shown in mm Dimensions subject to modification 57...

Page 58: ...Kalfire W90 47CR All dimensions shown in mm Dimensions subject to modification 58...

Page 59: ...Kalfire W90 47S All dimensions shown in mm Dimensions subject to modification 59...

Page 60: ...Kalfire W100 61F All dimensions shown in mm Dimensions subject to modification 60...

Page 61: ...Kalfire W105 47F All dimensions shown in mm Dimensions subject to modification 61...

Page 62: ...Kalfire W105 47T All dimensions shown in mm Dimensions subject to modification 62...

Page 63: ...Kalfire W120 38F All dimensions shown in mm Dimensions subject to modification 63...

Page 64: ...0 kW 15 9 kW 109 82 0 78 0 Kalfire W66 48S A 13 3 kW 16 6 kW 106 80 0 80 0 Kalfire W70 33F A 12 0 kW 15 0 kW 106 80 0 80 0 Kalfire W71 62F A 16 0 kW 19 3 kW 110 83 0 79 0 Kalfire W80 52T A 16 8 kW 21...