3.6.2 Reducer ring
The Kalfire W is delivered as standard with a reducer ring
(except for Kalfire W66/48S). This ring can be used to
connect various flue systems to the Kalfire.
Table 4: Diameter chimney connection collar
Kalfire type
Connection collar (mm)
A (mm)
B (mm)
C (mm)
W45/48F
Ø148 ±2
Ø156 ±1
Ø136 ±1
Ø152 ±1
W60/51F, W70/33F
Ø178 ±2
Ø186 ±1
Ø166 ±1
Ø182 ±1
W85/40F
Ø198 ±2
Ø206 ±1
Ø186 ±1
Ø202 ±1
W71/62F, W100/61F,
W105/47F, W120/38F
Ø248 ±2
Ø256 ±1
Ø236 ±1
Ø248 ±1
W65/38C
Ø178 ±2
Ø186 ±1
Ø166 ±1
Ø182 ±1
W66/48S, W80/52T
Ø198 ±2
Ø206 ±1
Ø186 ±1
Ø202 ±1
W90/47C, W90/47S,
W105/47T
Ø248 ±2
Ø256 ±1
Ø236 ±1
Ø248 ±1
Kalfire W65/38C
Connection to a Ø200 flue duct is only possible with a chimney
duct of minimum 4.5 metres and maximum 6 metres long.
Kalfire W66/48S
Connection must remain Ø200 flue, reduction is not allowed.
Kalfire W90/47S
Connection to a Ø300 flue duct is only possible with a chimney
duct of minimum 4.5 metres and maximum 6 metres long.
Figure 2 Reducer ring
3.7 Mounting the damper
The Kalfire W is delivered as standard without a damper. A damper
can be used to influence the degree of draught (suction) in the
flue. With the Kalfire W an external damper can be added. If there
is too much suction in the flue, we advise you to use a damper.
The amount of draught can be tested when you ignite the fire to
test the operation of the appliance. Pay extra attention to this
aspect, if the flue is longer than 7 metres. Normally the Kalfire W
can be controlled well using the air regulation (see section 5.3).
Attention
•
Make sure that the position of the damper is visible for the
end user. For this purpose, most of the operating knobs
have a position indication
(Open = Auf or +, Closed = Zu or -).
•
Check the functioning of the damper before completing the
installation of the fireplace.
•
Make sure that the end user is familiar with way the damper
functions.
22
Summary of Contents for W Series
Page 1: ...Installation and user manual CLOSED WOOD FIRES DON T COMPROMISE EN...
Page 2: ......
Page 4: ...4...
Page 6: ...6...
Page 49: ...Kalfire W60 51F All dimensions shown in mm Dimensions subject to modification 49...
Page 50: ...Kalfire W65 38CL All dimensions shown in mm Dimensions subject to modification 50...
Page 51: ...Kalfire W65 38CR All dimensions shown in mm Dimensions subject to modification 51...
Page 52: ...Kalfire W66 48S All dimensions shown in mm Dimensions subject to modification 52...
Page 53: ...Kalfire W70 33F All dimensions shown in mm Dimensions subject to modification 53...
Page 54: ...Kalfire W71 62F All dimensions shown in mm Dimensions subject to modification 54...
Page 55: ...Kalfire W80 52T All dimensions shown in mm Dimensions subject to modification 55...
Page 56: ...Kalfire W85 40F All dimensions shown in mm Dimensions subject to modification 56...
Page 57: ...Kalfire W90 47CL All dimensions shown in mm Dimensions subject to modification 57...
Page 58: ...Kalfire W90 47CR All dimensions shown in mm Dimensions subject to modification 58...
Page 59: ...Kalfire W90 47S All dimensions shown in mm Dimensions subject to modification 59...
Page 60: ...Kalfire W100 61F All dimensions shown in mm Dimensions subject to modification 60...
Page 61: ...Kalfire W105 47F All dimensions shown in mm Dimensions subject to modification 61...
Page 62: ...Kalfire W105 47T All dimensions shown in mm Dimensions subject to modification 62...
Page 63: ...Kalfire W120 38F All dimensions shown in mm Dimensions subject to modification 63...
Page 67: ......
Page 68: ...Gelo rveldweg 21 5951 DH Belfeld info kalfire nl KALFIRE COM DON T COMPROMISE REF V01 2018 EN...