Finish the front platform of the Kalfire W65/38C, W66/48S,
W90/47C and W90/47S
The front of the Kalfire W65/38C, W66/48S, W90/47C and
W90/47S can be finished in two ways:
•
Mount the platform under the steel design trim.
•
Mount the platform agains the steel design trim (at the
same height).
The platform may not touch the steel design trim leave at
least 2 mm between the platform and the steel design trim.
Table 5: Technical data
Kalfire type
W45/48F
W60/51F
W65/38C
W66/48S
W70/33F
W71/62F
W80/52T
W85/40F
Indication plate
P8-086-
2009
P8-003-
2015
P8-020-
2014
P8 054-
2015
P8-017-2
015
P8-025-
2011
P8-070-
2015
P8-001-
2015
Inspection body
1004
1004
1004
1004
1004
1004
1004
1004
Norm
EN13229 A2 EN13229 A2 EN13229 A2 EN13229 A2 EN13229 A2 EN13229 A2 EN13229 A2 EN13229 A2
Output (kW)
4.7-9.3
6.6-13.2
6.5-13
6.7-13.3
6-12
8-16.0
8.4-16.8
7.4-14.8
Flue gas mass flow (g/s)
6.8
11.3
10.2
13.04
10.3
12.7
15.8
13.2
Heat output (%)
86
81
82
80
80
83
80
81
Energy efficiency class
A+
A+
A+
A
A
A+
A
A+
Energy efficiency Index (%)
115
108
109
106
106
110
106
108
Flue gas temperature (°C)
270
260
257
247
282
302
262
257
CO at 13%O2 (%)
0.10
0.08
0.1
0.07
0.09
0.10
0.09
0.06
CO2 content (%)
11.1
10.1
10.8
8.8
10.5
10.6
9.3
9.72
Dust content at 13%O2 (mg/nm³)
36
13
35
10
34
11
12.8
17
NOx at 13%O2 (mg/nm³)
150
119
94
111
87
113
119
80.7
CnHm at 13%O2 (mg/nm³)
58
58
82
49
74
61
65
25.6
Min. flue draught (Pa)
12
12
13
12
11
12
12
11.6
Insulation side panel (cm)
(AGI-Q 132, table 1)
5
10
5
10
10
10
-
10
Insulation rear panel (cm)
(AGI-Q 132, table 1)
5
10
5
10
10
10
10
10
Insulation base (cm)
(AGI-Q 132, table 1)
0
0
0
0
0
0
0
0
Insulation roof (cm)
(AGI-Q 132, table 1)
9
9
9
9
9
9
9
9
Flue connection (mm)
¢150
¢180
¢180/200
¢200
¢180
¢250
¢200
¢200
Combustion air connection (mm)
1× Ø150
1× Ø150
2× Ø150
2× Ø150
2× Ø150
2× Ø150
2× Ø150
2× Ø150
Convection connection
inlet (mm)
2× Ø150
2× Ø150
2× Ø150
2x Ø150
4× Ø150
4× Ø150
2× Ø150
4× Ø150
Convection connection
outlet (mm)
2× Ø150
2× Ø150
2× Ø150
2× Ø150
4× Ø150
4× Ø150
2× Ø150
4× Ø150
Weight (kg)
180
226
270
270
210
271
385
257
29
Summary of Contents for W Series
Page 1: ...Installation and user manual CLOSED WOOD FIRES DON T COMPROMISE EN...
Page 2: ......
Page 4: ...4...
Page 6: ...6...
Page 49: ...Kalfire W60 51F All dimensions shown in mm Dimensions subject to modification 49...
Page 50: ...Kalfire W65 38CL All dimensions shown in mm Dimensions subject to modification 50...
Page 51: ...Kalfire W65 38CR All dimensions shown in mm Dimensions subject to modification 51...
Page 52: ...Kalfire W66 48S All dimensions shown in mm Dimensions subject to modification 52...
Page 53: ...Kalfire W70 33F All dimensions shown in mm Dimensions subject to modification 53...
Page 54: ...Kalfire W71 62F All dimensions shown in mm Dimensions subject to modification 54...
Page 55: ...Kalfire W80 52T All dimensions shown in mm Dimensions subject to modification 55...
Page 56: ...Kalfire W85 40F All dimensions shown in mm Dimensions subject to modification 56...
Page 57: ...Kalfire W90 47CL All dimensions shown in mm Dimensions subject to modification 57...
Page 58: ...Kalfire W90 47CR All dimensions shown in mm Dimensions subject to modification 58...
Page 59: ...Kalfire W90 47S All dimensions shown in mm Dimensions subject to modification 59...
Page 60: ...Kalfire W100 61F All dimensions shown in mm Dimensions subject to modification 60...
Page 61: ...Kalfire W105 47F All dimensions shown in mm Dimensions subject to modification 61...
Page 62: ...Kalfire W105 47T All dimensions shown in mm Dimensions subject to modification 62...
Page 63: ...Kalfire W120 38F All dimensions shown in mm Dimensions subject to modification 63...
Page 67: ......
Page 68: ...Gelo rveldweg 21 5951 DH Belfeld info kalfire nl KALFIRE COM DON T COMPROMISE REF V01 2018 EN...