For the Kalfire W65/38C, the mantle iron and roll of felt should be
ordered separately, it’s not included in the convection set.
This convection set is ordered separately to the fireplace. Instead
of a grill, openings (for example recessed plinths) can be used. Do
not reduce the convection openings.
Place all grills/openings, both upper and lower, to facilitate the
natural circulation. The gratings/openings should be situated in
the same pressure area (the same room) as the fireplace.
Kalfire W66/48S and W80/52T
•
Two flexible aluminium hoses Ø150 mm, 1.25 m (one hose of
2.5 m that is divided into two hoses).
•
Eight hose brackets.
•
Four grills (outer dimensions 20 cm × 20 cm, recess
dimension 16.5 cm × 16.5 cm, with connection collar
Ø150 mm).
For the Kalfire W66/48S, the mantle iron and roll of felt should be
ordered separately, it’s not included in the convection set.
This convection set is ordered separately to the fireplace. Instead
of a grill, openings (for example recessed plinths) can be used. Do
not reduce the convection openings.
Place all grills/openings, both upper and lower, to facilitate the
natural circulation. The gratings/openings should be situated in
the same pressure area (the same room) as the fireplace.
Kalfire W90/47C
•
Four flexible aluminium hoses Ø150 mm, 1.25 m
(two hoses of 2.5 m that are divided into four hoses.
•
Eight hose brackets.
•
Four grills (outer dimensions 20 cm × 20 cm, recess
dimension 16.5 cm × 16.5 cm, with connection collar
Ø150 mm).
For the Kalfire W90/47C, the mantle iron and roll of felt should be
ordered separately, it’s not included in the convection set.
This convection set is ordered separately to the Kalfire W90/47C.
Instead of a grill, openings (for example recessed plinths) can be
used. Do not reduce the convection openings.
Place all grills/openings, both upper and lower, to facilitate the
natural circulation. The gratings/openings should be situated in
the same pressure area (the same room) as the fireplace.
Kalfire W90/47S
•
Two flexible aluminium hoses Ø150 mm, 1.25 m
(one hose of 2.5 m that is divided into two hoses).
•
Four hose brackets.
•
Two grills (outer dimensions 20 cm × 20 cm, recess
dimension 16.5 cm × 16.5 cm, with connection collar
Ø150 mm).
•
Two grills (outer dimensions 35 cm × 20 cm, recess
dimension 33 cm × 16.5 cm, with connection collar
Ø150 mm).
For the Kalfire W90/47S, the mantle iron and roll of felt should be
ordered separately, it’s not included in the convection set.
This convection set is ordered separately to the fireplace. Instead
of a grill, openings (for example recessed plinths) can be used. Do
not reduce the convection openings.
Place all grills/openings, both upper and lower, to facilitate the
natural circulation. The gratings/openings should be situated in
the same pressure area (the same room) as the fireplace.
The supporting frame (including accessories) of the Kalfire
W90/47S must be ordered separately.
Kalfire W105/47T
•
Four flexible aluminium hoses Ø150 mm, 1.25 m
(two hoses of 2.5 m that are divided into four hoses).
•
Four flexible aluminium hoses Ø150 mm, 0.62 m
(one hose of 2.5 m that is divided into four hoses).
•
Sixteen clamping strips.
•
Four gratings (outer dimensions 35 cm × 20 cm, recess
dimension 33 cm × 16.5 cm, with two connection collars
Ø150 mm each).
•
Mantel iron; this must be sawn to the correct size.
•
Roll of felt to create an expansion joint between the metal
of the mantel iron and the surround.
Method when using convection grills
Ensure that, at the base, there is sufficient supply for the cold
convection air from the room (see table below). At the top
connect the grills to the outlet openings of the warm convection
air (see table below).
Table 2: Through put openings for convection air
Kalfire type
W45/48F
W60/51F
W65/38C
W66/48S
W80/52T
W90/47S
W70/33F
W71/62F
W85/40F
W90/47C
W105/47T
W100/61F
W105/47F
W120/38F
Inlet
convection air
2× Ø150 mm
4× Ø150 mm
355 cm²
705 cm²
Outlet
convection air
2× Ø150 mm
4× Ø150 mm
355 cm²
705 cm²
Attention! When mounting the gratings, ensure they are placed in
such a position, that they cannot become blocked.
17
Summary of Contents for W Series
Page 1: ...Installation and user manual CLOSED WOOD FIRES DON T COMPROMISE EN...
Page 2: ......
Page 4: ...4...
Page 6: ...6...
Page 49: ...Kalfire W60 51F All dimensions shown in mm Dimensions subject to modification 49...
Page 50: ...Kalfire W65 38CL All dimensions shown in mm Dimensions subject to modification 50...
Page 51: ...Kalfire W65 38CR All dimensions shown in mm Dimensions subject to modification 51...
Page 52: ...Kalfire W66 48S All dimensions shown in mm Dimensions subject to modification 52...
Page 53: ...Kalfire W70 33F All dimensions shown in mm Dimensions subject to modification 53...
Page 54: ...Kalfire W71 62F All dimensions shown in mm Dimensions subject to modification 54...
Page 55: ...Kalfire W80 52T All dimensions shown in mm Dimensions subject to modification 55...
Page 56: ...Kalfire W85 40F All dimensions shown in mm Dimensions subject to modification 56...
Page 57: ...Kalfire W90 47CL All dimensions shown in mm Dimensions subject to modification 57...
Page 58: ...Kalfire W90 47CR All dimensions shown in mm Dimensions subject to modification 58...
Page 59: ...Kalfire W90 47S All dimensions shown in mm Dimensions subject to modification 59...
Page 60: ...Kalfire W100 61F All dimensions shown in mm Dimensions subject to modification 60...
Page 61: ...Kalfire W105 47F All dimensions shown in mm Dimensions subject to modification 61...
Page 62: ...Kalfire W105 47T All dimensions shown in mm Dimensions subject to modification 62...
Page 63: ...Kalfire W120 38F All dimensions shown in mm Dimensions subject to modification 63...
Page 67: ......
Page 68: ...Gelo rveldweg 21 5951 DH Belfeld info kalfire nl KALFIRE COM DON T COMPROMISE REF V01 2018 EN...