Kalatel DSR-1000eZ
1-6
0150-0238B
DB-9 Pin Configuration for Serial Port
Pin
Use
Pin
Use
Pin
Use
1
DCD
4
Not Connected
7
RTS
2
RX
5
Ground
8
CTS
3
TX
6
Not Connected
9
Not Connected
1
5
6
9
DB-9 Connector on
Back Panel
Video Input and Output
The unit is equipped with a Composite video input
and output. The video input is auto terminating.
Composite Input:
75 Ohm BNC connector.
Composite Output:
75 Ohm BNC connector.
Composite Looping:
Yes, while unit is On or Off.
1.8 Accessories I/O Port
ACCESSORIES
1
5
6
9
The back panel of the unit is equipped with an Accessories Port (DB-9
style connector). Connect the Accessories PCB (supplied with the unit) to
the Accessories Port. Wire all accessories to the Accessories PCB.
Do not attempt to wire accessories directly to the DB-9 connector.
If the Accessories PCB is lost or missing, contact GE Interlogix Customer
Service for a replacement (Part Number 0900-0127a). As a substitute,
purchase a female DB-9 connector and make all connections as shown in
this section.
DB-9 Connector on
Back Panel
Pin 1:
Alarm In.
Pin 2:
Alarm Out.
Pin 3:
Record Start In.
Pin 4:
Alarm Record Reset.
Pin 5:
VEXT Pulse Out.
Pin 6:
Error Out.
Pin 7:
Ground.
Pin 8:
Videoloss Out.
Pin 9:
Disk End Out.
Pin 10:
Ground.
1
2
3
4
5
6
7
8
9
GND
Accessories PCB
Alarm In
An alarm condition can be activated by an Active Low TTL input
or by relay contact devices such as pressure pads, passive
infrareds, door switches, or other similar devices.
Input:
Active Low TTL w/ pull-ups
or Normally Open Relay.
High:
5V (12V tolerant)
Low:
Ground
Minimum Duration: 0.5 Seconds