Description of individual screen elements:
Note:
1 – Temperature offset is a reference temperature value.
2 – Calculation formula: Corrected temperature = - slope * current AT + offset.
In the case of temperature presentation in Fahrenheit degrees, the following calculation formula
will be automatically applied: Corrected target temperature = - slope * (current temp. - 32) +
offset.
To set up the temperature curve: The temperature curve function involves two parameters: slope
and offset. To determine the slope and offset, linear regression is used.
13.5.2. Disabling the temperature curve:
After deactivating temperature compensation for zone 2, the status of the temperature curve will
change to “Not used.”
1
Click to return to the previous interface.
2
Target temperature at an outside temperature of 0°C (0~85).
3
Slope of the temperature curve (0~3.5).
4
Button to activate temperature compensation.