6. Inspection
6.1. Preparation for Inspection and Maintenance
• Perform tasks only when you are competent and have knowledge of the special properties and
hazards associated with refrigerant R290.
• The product contains flammable refrigerant R290. In the event of a leak, the released refriger
ant may mix with air, creating a flammable atmosphere.
• There is a risk of fire and explosion.
• Ensure that the space around the device is adequately ventilated
• Before engaging in inspection, maintenance, or replacement of parts, adhere to safety principles
• Disconnect the device from power and ensure that the product is correctly grounded.
5. Maintenance
Periodic maintenance (every 12 months).
To ensure proper operation of the device and maintain the warranty, arrange inspection by an
authorized Service Partner before 12 months of commissioning.
Before the initial device startup or after a prolonged pause, the following preparations should
be performed
1. Thoroughly inspect and clean the device
2. Clean the water system – mesh filter.
3. Check the water pump, regulating valve, and other water system components
4. Tighten all pipe connections
Do not change system parameters before consulting with engineer
Ensure that the water supply and drainage device is functioning correctly; otherwise, the
efficiency and reliability of the device may be compromised.
Ensure that water installations are clean and avoid dirt and blockages.
Check the current, water, and replace faulty parts at appropriate intervals.
Please use parts supplied or recommended by the manufacturer; do not use non-original parts.
If you need to replenish refrigerant due to a leak, contact the service or the sellers.
Zagrożenie!
Risk of death due to fire or explosion in case of refrigerant leakage!