![background image](http://html1.mh-extra.com/html/kaeser-kompressoren/sx/sx_service-manual_3193211037.webp)
Item Description
Function
12
Display field
Alphanumeric display with 4 lines.
13
Alarm
Flashes red when an alarm occurs.
Lights continuously when acknowledged.
15
Warning
Lights yellow for:
■ maintenance work due,
■ warning messages
16
Controller power Lights green when the power supply to the controller is switched on.
19
Machine ON
Lights green when the machine switched on.
Tab. 33 Indicators
4.9 SIGMA CONTROL BASIC function
4.9.1 Display layout
x x . x
b a r
Line 1
y y ° C
Line 2
z 0 0 0 0
h
Line 3
1 2 3 4 5 6 7 8 S p T i
Line 4
Line Display Meaning
1
xx.x
Current system pressure in bar, psi or MPa.
2
yy
Current airend discharge temperature (ADT) in °C or °F.
3
z
Display of parameters and their settings(see table 35)
4
1, 2, ... Error code for alarm and warning messages (see table 39 and table 40).
Operating state: LOAD:
Operating state: IDLE:
Tab. 34 Display
4.9.2 Parameter
Parameter Meaning
0
Operating hours counter
Displays the total time the drive motor was switched on.
Only KAESER Service has the right to change these parameters.
1
Load hours counter
Shows the total time the drive motor has run under LOAD.
Only KAESER Service has the right to change these parameters.
4
Design and Function
4.9
SIGMA CONTROL BASIC function
9_6919 04 E
Service Manual Screw Compressor
SX SIGMA CONTROL BASIC
27
Summary of Contents for SX
Page 2: ...Original instructions KKW SSX 1 04 en SBA SCHRAUBEN SCB...
Page 6: ...Contents iv Service Manual Screw Compressor SX SIGMA CONTROL BASIC 9_6919 04 E...
Page 8: ...List of Illustrations vi Service Manual Screw Compressor SX SIGMA CONTROL BASIC 9_6919 04 E...
Page 10: ...List of Tables viii Service Manual Screw Compressor SX SIGMA CONTROL BASIC 9_6919 04 E...