Transporting with a crane
Non-compliance with the safety regulations for load suspension and hoisting equipment may cause
severe accidents during lifting and moving the machine with cranes.
➤ Do not enter the danger zone while the machine is being lifted.
➤ Never lift and move the machine over people or occupied buildings.
➤ Avoid extreme weight shifting caused by additional loads or additions (tilting).
➤ Do not exceed the lifting capacity on the machine's lifting point (lifting eye).
➤ Only the designated lifting point should be used to attach lifting gear and under no circumstan‐
ces are handles, tow-bar or other components to be used.
➤ Use only hooks and shackles that comply with local safety regulations
➤ Do not attach cables, chains or ropes directly to the machine's lifting eye.
➤ Do not manipulate the crane suspension system, in particular the holding points of the crane
lifting eye.
➤ If screwed crane fixings had to be removed, please use only new self-locking nuts when instal‐
ling.
➤ Avoid jerking when lifting, as this may damage components.
➤ Loads must be slowly lifted and carefully set down.
➤ Never allow the load to hang from the crane longer than necessary.
The following are forbidden:
■ Air transport of the machine by slinging beneath a helicopter.
■ Dropping the machine by parachute.
3.5.3.2 Installation
The operator must ensure that only authorised personnel has access to the machine.
General instructions
A suitable installation location for the machine prevents accidents and faults.
➤ Do not position the machine under a low roof or covering. A build up of heat from the exhaust
can damage the machine.
➤ Ensure accessibility so that all work on the machine can be carried out without danger or hin‐
drance.
➤ Do not operate in areas in which specific requirements with regard to explosion protection are
in force.
For instance, the requirements of ATEX directive 94/9/EC "Equipment and Protective Systems
intended for use in Potentially Explosive Atmospheres".
➤ Ensure adequate ventilation.
➤ Place the machine in such a manner that the working conditions in its environment are not im‐
paired.
➤ Comply with limit values for ambient temperature and humidity.
➤ The intake air must not contain any damaging contaminants,
Damaging contaminants are for instance:
■ Exhaust gases from combustion engines,
3
Safety and Responsibility
3.5
Dangers
No.: 9_9570 07 USE
Operator Manual Screw Compressor
M250 SIGMA CONTROL MOBIL