ATENCIÓN
Damage to the device from electrostatic discharge
Components inside the device can be damaged beyond repair by static discharge.
›
Note the ESD protective measures.
›
Earth yourself before touching a component by touching a grounded object.
AVISO
Due to the installation position of the communication circuit board, this must be specially safeguarded
against moisture and exposure to dust.
›
Make sure that no moisture or dust impacts on the circuit board during installation. Moisture and dust
particles must be removed immediately. In doing so, disassembly of the circuit board may be neces-
sary.
All interfaces are located on the communication circuit board on the inside of the housing door.
RS485
Ethernet
A B
GND
A B
GND
H L
H L
USB
ERR
Optional
INV
OFF
Optional
Optional
DIP
2
1
3
4
5
6
7
Fig. 33: Communication circuit board: Connection and assignment of the interfaces
1
Communication circuit board
5
RS485 – Connection for data loggers
2
ERR – Connection for fault signal relay
6
DIP switch – Activate terminator
3
USB – Connection for update
7
INV OFF – Connection for remote controls
4
Ethernet – Connection for communication
7.9.2
Insert and lay the cables
Inserción de los cables de interfaz
1 Suelte y retire la tapa del racor [W_29/W_20]].
2 Retire la junta.
3 Haga pasar el cable de conexión por la tapa del racor y por la junta.
4 Coloque la junta en el racor.
5 Anschlusskabel in den Anschlussbereich durchführen.
»
Continuar con la conexión.
1
2
Fig. 34:
Insert the Ethernet cable
1
Cable fitting for pass the
Ethernet cable
2
Cable fitting for pass the sig-
nal cable
Kaco blueplanet 29.0TL3
Página 30
ES