background image

User manual HRE-serie version 6, November 2013 

 

23

 

Appendix G CE certification 

 

 

 
 
 
 
 
 

Summary of Contents for HRE300

Page 1: ...User manual Kabola HRE serie Kabola Heating Systems BV Placotiweg 1E 4131 NL Vianen Utr Nederland...

Page 2: ...lowing way Hint This gives the user suggestions and advises to facilitate the execution of certain tasks Attention Additional information is supplied to the user and possible problems are indicated Wa...

Page 3: ...central heating system 8 4 1 3 Flue gas outlet 8 4 1 5 Electrical connection 10 4 1 6 Filling the central heating system 11 4 1 7 Mounting the oil burner 12 4 1 8 Mounting the oil filter and oil burne...

Page 4: ...e designed to generate heat for the heating of water for a central heating system The dimensions of the rooms to be heated have to be taken into consideration These boilers are not designed for direct...

Page 5: ...s In this chapter we emphasizes the safety related points for operating the boiler MEASURES FOR A SAFE INSTALLATION Don t store any flammable and or gaseous products in the room where the boiler is in...

Page 6: ...5 replacing the burner While transporting the boiler take following precautions Don t damage the boiler use a blanket to cover the boiler Transport the boiler standing up 3 2 Storage Take the followi...

Page 7: ...Fitting the boiler Install the boiler in a dry place Install the boiler on a firm horizontal base Make sure there is sufficient supply of fresh air in the room where the boiler is installed see hint...

Page 8: ...an of your boiler considerably and has a negative impact on the efficiency Remember when installing the flue that even the best boiler won t work properly unless the flue is properly installed Warning...

Page 9: ...ery elbow of 90 is equivalent to 1 meter straight pipe VERTICAL FLUE GAS OUTLET This way if installation is preferable for seagoing boats and sailing boats because these boats encounter large angles o...

Page 10: ...a wire with 2 cores 0 75 mm 2 isolated hose The room thermostat you need to connect at the following way Remove the lid from the connector A figure 5a what is mounted at the back of the dashboard Con...

Page 11: ...system slowly with water until the pressure indicator indicates a pressure of 2 bar Close the valve 2 Bleed the CH system If necessary fill with water again up to 2 bar of pressure Switch on the boil...

Page 12: ...e below see also figure 9 Remove the burner cover from the oil burner 1 Connect the oil pump 2 to the oil filter 3 using the included fuel hoses Make sure that the flow directions on the pump comply w...

Page 13: ...ions for leaks 4 8 1 If the burner does not start the control light will light 4 8 2 Close the bleed valve 3B on the oil filter 4 8 3 Wait approximately 3 minutes 4 8 4 Reset the burner by pushing but...

Page 14: ...anation of the dashboard Explanation from the number in the figure 13 A Fuse holder with a glass fuse 10A 230V B On off switch C Analogue display for boiler temperature D Adjust nob for boiler tempera...

Page 15: ...or a service engineer from Kabola Heating Systems Every year 1 Clean the boiler 1 1 Remove the burner see 4 1 5 1 2 Remove the burner from the boiler 1 3 Open the door of the boiler 1 4 Remove the ins...

Page 16: ...40 140 140 J 75 75 75 Technical specifications HRE300 HRE400 HRE500 Flue gas mm 60 80 80 C H connection mm 22 22 22 Max capacity kW 8 10 10 14 20 Service pressure Bar 2 2 2 Working pressure Bar 3 3 3...

Page 17: ...User manual HRE serie version 6 November 2013 17 Appendix B Electrical diagram 230 V...

Page 18: ...imal thermostat Burner stops Reset burner once Flame protection dirty photo cell Clean glass of flame protection Flame protection defect photo cell Replace flame protection Burner starts pulsing Flue...

Page 19: ...12 Stainless steel eficiency tube HRE500 14 N225 13 Insulation door 294 x 294 x 20 mm HRE300 9 I081 13 Insulation door 300 x 300 x 20 mm HRE400 9 I082 13 Insulation door 355 x 300 x 20 mm HRE500 9 I09...

Page 20: ...User manual HRE serie version 6 November 2013 20 Appendix E Burner parts...

Page 21: ...ector 35 041 13 Burner automat Siemens LMO24 14 7 Pole connector 4 D164 15 Adjust mutter 16 Fixing mutter 17 Pilar burner cap 18 Photo cel 4 D037 19 Motor 20 Motor cable 21 Oil pump 35 015 22 Cable wi...

Page 22: ...lands decIare under our own responsibility that the product Kabola HRE300 HRE400 HRE500 230 V to which this declaration relates complies with the fol owing standards EN 303 1 EN 303 2 EN 304 EN 50081...

Page 23: ...User manual HRE serie version 6 November 2013 23 Appendix G CE certification...

Reviews: