User manual HRE-serie version 6, November 2013
12
Figure 10
4.1.7 Mounting the oil burner
Follow the instruction below for mounting the oil burner:
Passionate the insulation (2) and the burner clamp (3)
that they are in one line with the mounting holes in the
door.
Assemble the burner clamp with the 4 M8 bolts. The
arrow at the burner clamp must point to the top.
Hint:
Smear some sealant in the crack in
the flange to seal
Slide the burner trough the burner clamp and push it
as far as possible.
Fasten the screw from the burner clamp what is
clamping the burner.
Attention:
Take care that the flame tube is not
damaged during installation. Repairs
to the flame tube are very expensive
and don't fall under warranty.
4.1.8 Mounting the oil filter and oil burner.
To connect the filter to the burner follow the procedure below
(see also figure 9):
Remove the burner cover from the oil burner (1);
Connect the oil pump (2) to the oil filter (3), using the
included fuel hoses. Make sure that the flow
directions on the pump comply with those on the filter;
Connect the fuel line from the tank to the filter (5A).
The fuel line must have an outer diameter of 8 mm
and must be made from copper or steel. The fuel line
has to be connected directly to the oil tank. Correct
functioning of the burner can not be guaranteed when a fuel manifold or T connection is
installed;
Connect the plug (4) from the boiler to the burner.
Hint:
When the oil tank is situated below
the boiler or when the oil supply line
comes from below the boiler, it is
advisable to use a self bleeding oil
filter. The articlenumber 4-D133
(figure 11) standard the 4-D131
(figure 12) is supplied with the set.
This
prevents
unnecessary
malfunctioning of the burner. In the
manual of the burner you will find an
overview
with
the
allowed
dimensions of the oil supply line.
Figure 9
Figure 11