background image

10

6. Example of Complete Entry:

005#06#

.

7. Enter another

#

to indicate the end of programming.

8. In this example, the lock will remain unlocked for six hours, starting from

the time you activate it in Passage Mode.

9. You have now configured the duration of the Passage Mode period for

that lock. This does

NOT

initiate Passage Mode until you activate the

Passage Mode - See Procedure 12 on “How to activate/deactivate the

Passage Mode.”

10. The new length of time will take effect the next time you put a lock into

Passage Mode by following the correct command sequence.

PROCEDURE 6 - PROGRAM THE LOCK FOR TAMPER

TIME PARAMETERS

You can set a Tamper Time Wrong Tries parameter referring to the number

of times the wrong code can be entered before the lock goes into Tamper

Shutdown Mode.

For example, if you program the lock to accept three wrong tries, the lock will

tolerate three wrong entries, staying locked but providing visual feedback (see

visual message chart in rear section). After that, it will go into a Tamper

Shutdown Mode and remain locked until the end of the Tamper Shutdown Time

period - the length of that period is configured in Step 4 of this procedure

(below).

Required User Level: Master, Manager

1. Set the tamper time for the period of time during which the keypad will

remain inaccessible after the specified number of wrong Access Codes

are entered

2. Put the lock into Pushbutton Programming Mode.

3. Enter the code as follows -

006#TT#

(

TT

is seconds -

00 to 90

seconds).

4. Example of Complete Entry:

006#60#

. (for 60 seconds)

5. Enter the code as follows:

007 #TT#

(

TT

is number of wrong entries -

03

to

09

), let’s use

05

for example.

6. Example of Complete Entry:

007#05#

.

7. Enter another

#

to indicate the end of programming.

8. The lock will stay locked after three wrong entries for the length of time

you select in the steps below,

even if a valid code (including the

Master or a Manager Code) is entered after the three wrong codes.

Only the mechanical key override will open the lock during the

tamper shut down Period.

9. Enter another

#

to indicate the end of programming.

Summary of Contents for E-PLEX 50XX SERIES

Page 1: ...OPERATIONS MANUAL E PLEX 50XX 30XX SERIES...

Page 2: ...Passage Mode Period Procedure 6 Program the Lock for Tamper 10 Time Parameters Procedure 7 Programming the Lock for Keypad 11 Buzzer Volume Users General Information 11 User Levels 12 User Codes 13 U...

Page 3: ...ushbutton Programming Commands 31 Visual Feedback Message Definitions 34 User List Table 35 TABLE OF CONTENTS continued A publication of Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105...

Page 4: ...e E Plex Lock is in the Pushbutton Programming Mode the Master Manager can enter one or more command sequences Each command sequence ends with a character that acts like an enter character At the very...

Page 5: ...r shutdown time 30 seconds Tamper attempt count 4 attempts Access code length 4 digits Latch Holdback Mode Disabled E 30xx only Swingbolt Privilege Disabled E 30xx only Privacy Privilege Disabled E 50...

Page 6: ...finished The serves another purpose to distinguish a program ming type command from a simple Access Code to open the door A Master or Manager User can use the same number to open the door or to put th...

Page 7: ...he E Plex Lock programmable pushbutton lock it must first be placed in Programming Mode Important This is the only programmable function that can be done during the factory mode using the factory mast...

Page 8: ...me the software package will make the adjustment for Daylight Savings Time These must be regularly updated according to your maintenance schedule Enter 001 for date settings and 002 for time settings...

Page 9: ...Example of Complete Entry 004 10 9 Enter another to indicate the end of programming 10 You have now programmed the lock ID 1234 and for example an Unlock Time of 10 seconds for the door PROCEDURE 5 PR...

Page 10: ...ck see visual message chart in rear section After that it will go into a Tamper Shutdown Mode and remain locked until the end of the Tamper Shutdown Time period the length of that period is configured...

Page 11: ...ing the Access Code without signs Put the lock into Pushbutton Programming Mode by entering before and after their Access Code 2 Each user Manager User Service User or Access User occupies one of the...

Page 12: ...configurable period of time This period of time starts on the first use of the code Each Service User combina tion is automatically deleted from the locks memory after its period of time expires The n...

Page 13: ...need access to the lock delete the User Code by deleting the corresponding user ID location This permits you to use the deleted user ID location for a new user If you only de activate the old code you...

Page 14: ...r with a Manager Access Code If you change the Access Code for an existing Manager the procedure is the same Required User Level Master 1 Put the lock into Pushbutton Programming Mode 2 Enter command...

Page 15: ...ccess Code of 00 you can only enter the door once If the door shuts upon exiting you will not be able to re enter This type of access is called a one shot code 7 Example of Complete Entry 102 025 2240...

Page 16: ...lock is used with a wall bumper the warranty is null and void If a doorstop is required we recommend the use of a floor secured stop The environment and conditions of use determine the life of finishe...

Page 17: ...CONTROL 2941 INDIANA AVENUE WINSTON SALEM NC 27199 3770 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 1563 POSTAGE WILL BE PAID BY ADDRESSEE WINST...

Page 18: ...Exercise Room This lock is New Installation Replacing a conventional keyed lock Replacing a Kaba Mechanical Pushbutton Lock Replacing a Kaba Electronic Access Control Replacing a Keyless Lock other t...

Page 19: ...Notes Notes 19...

Page 20: ...20 Notes...

Page 21: ...21 Notes...

Page 22: ...Service User Access Code is automatically deleted from the lock at the end of its specified length of time However use this procedure if you want to delete the code earlier than the specified expiry t...

Page 23: ...o Pushbutton Programming Mode 2 Enter Command 300 to activate a User Code 3 Enter the ID location NNN where NNN is the specific User ID location 023 for example 4 Example of complete entry 300 023 5 E...

Page 24: ...that are temporarily inactive Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 Enter Command 398 3 Example of Complete Entry 398 4 Enter another to indicate the end...

Page 25: ...1 Put the lock into Pushbutton Programming Mode 2 Enter Command 400 to de activate User Access Codes 3 Enter the code 400 NNN where NNN is the specific User ID location 023 for example 4 Example of co...

Page 26: ...ive excluding Master Manager and M Unit Codes Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 Enter Command 498 to de activate all Access and Service Codes 3 Examp...

Page 27: ...the end of the code there could be a problem with the pushbutton electronics 8 Try the Diagnostic Code again 500 1234567890 to be sure you entered all the numbers correctly and in the correct order 9...

Page 28: ...led Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 If it was disabled enter the command 014 to Enable Disable the Latch Holdback mode followed by 1 to Enable this...

Page 29: ...will behave as though it is in a latch holdback mode since the swingbolt is completely retracted and stays retracted thus allowing free access without any codes You perform the same sequence of opera...

Page 30: ...the thumbturn on the lock front housing clockwise and hold The swingbolt will revert back up to its locked horizontal home position Let go off the thumbturn so that it will also revert back to its nor...

Page 31: ...p TT 02 to 20 seconds Passage Mode Timeout setup TT 01 to 24 hours duration time in hours 00 no time limit Tamper time setup TT 00 to 90 seconds Tamper wrong try setup TT 03 to 09 Buzzer volume contro...

Page 32: ...ation 001 to 299 Combination length can be 4 to 8 digits depending on access length LL setting Add Modify Service User Access Code NNN specific User ID location 001 to 299 HH 01 to 24 hours duration t...

Page 33: ...User Activate De Activate Passage Mode P 0 or 1 0 disable Passage Mode 1 enable Passage Mode De Activate User Access Code NNN specific User ID location 001 to 299 De Activate Manager Access Code NNN...

Page 34: ...entry including duplicate access code Tamper shutdown beginning OFF ON 2 sec Tamper shutdown state OFF ON 1 sec Tamper shutdown ending ON OFF 2 sec Communication starting ON OFF 1 sec Communication en...

Page 35: ...010 011 012 013 299 Access Code User Name User Type Optional Easy To Use software called E Plex Standard is also available for this product to program and maintain doors and users For more informatio...

Page 36: ...Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kabaaccess com www e plexlock com PKG3219 0408...

Reviews: