10
6. Example of Complete Entry:
005#06#
.
7. Enter another
#
to indicate the end of programming.
8. In this example, the lock will remain unlocked for six hours, starting from
the time you activate it in Passage Mode.
9. You have now configured the duration of the Passage Mode period for
that lock. This does
NOT
initiate Passage Mode until you activate the
Passage Mode - See Procedure 12 on “How to activate/deactivate the
Passage Mode.”
10. The new length of time will take effect the next time you put a lock into
Passage Mode by following the correct command sequence.
PROCEDURE 6 - PROGRAM THE LOCK FOR TAMPER
TIME PARAMETERS
You can set a Tamper Time Wrong Tries parameter referring to the number
of times the wrong code can be entered before the lock goes into Tamper
Shutdown Mode.
For example, if you program the lock to accept three wrong tries, the lock will
tolerate three wrong entries, staying locked but providing visual feedback (see
visual message chart in rear section). After that, it will go into a Tamper
Shutdown Mode and remain locked until the end of the Tamper Shutdown Time
period - the length of that period is configured in Step 4 of this procedure
(below).
Required User Level: Master, Manager
1. Set the tamper time for the period of time during which the keypad will
remain inaccessible after the specified number of wrong Access Codes
are entered
2. Put the lock into Pushbutton Programming Mode.
3. Enter the code as follows -
006#TT#
(
TT
is seconds -
00 to 90
seconds).
4. Example of Complete Entry:
006#60#
. (for 60 seconds)
5. Enter the code as follows:
007 #TT#
(
TT
is number of wrong entries -
03
to
09
), let’s use
05
for example.
6. Example of Complete Entry:
007#05#
.
7. Enter another
#
to indicate the end of programming.
8. The lock will stay locked after three wrong entries for the length of time
you select in the steps below,
even if a valid code (including the
Master or a Manager Code) is entered after the three wrong codes.
Only the mechanical key override will open the lock during the
tamper shut down Period.
9. Enter another
#
to indicate the end of programming.
Summary of Contents for E-PLEX 50XX SERIES
Page 1: ...OPERATIONS MANUAL E PLEX 50XX 30XX SERIES...
Page 19: ...Notes Notes 19...
Page 20: ...20 Notes...
Page 21: ...21 Notes...