8
Note: In Dual Combination Mode you may dial either combination fi rst to
confi rm. In Super/Sub Mode you must dial the Supervisory combination fi rst
and the Subordinate Combination second as you did when fi rst entering the
combinations.
15. Dial
right
(CW). After
OP
with a right arrow (
OP
en right) is displayed, continue dialing
to the right to retract the lock bolt.The new combinations have now been set.
Note: If you misdial or do not properly fi nish the Change Key sequence in
any way, the X-09 automatically reverts to the previous combination(s). The
old combination(s) remain valid until the process is completed successfully.
Caution:
After you have confi rmed the new combination(s), test dial the
combination(s)
before closing the door or container.
IF YOU LOCK THE CHANGE KEY IN THE SAFE
If the door of your container is shut and the X-09 is accidentally locked with the Change Key
still inserted in the back of the lock, you can recover with the following procedure.
1. Allow the lock to power down. (After 40 seconds, the display will go blank. Wait an
additional 2 minutes for full power down.)
2. Dial
right
(CW) until lock is “powered” and the number of successful openings is
fl ashing.
Caution: Do not continue to dial right once you see the fl ashing numbers on
the display.
3. Now dial the current combination(s) just as you would to open the lock ; i.e.,
left
(CCW)
to dial the fi rst number,
right
(CW) to dial the second number,
left
(CCW) to dial the
third number.
4. Dial
right
(CW). After
OP
with a right arrow (
OP
en right) is displayed, continue dialing
to the right to retract the lock bolt.
You may now restart the procedure to Set the Operating Mode and Change
Combination(s).
Note:
You cannot use the serial number in place of the combination for this
procedure. The combination must be known.