TO OPEN THE CDX-09 FROM THE INSIDE

1.  Turn the release knob to the left (counterclockwise) to withdraw the dead bolt. 

Note: 

When closing the CDX-09, the dead bolt will not extend until the release bolt 

hits the door strike as the door closes.

LIFE SAFETY OPERATION

The Life Safety Feature (Bolt Stop Assembly) is provided to prevent someone from 
unintentionally extending the lock bolt. 

TO ACTIVATE THE LIFE SAFETY FEATURE

1.  Turn the dial to the right (clockwise) to withdraw the lock bolt and also the 

dead bolt (Extension Bolt).

Note: 

The life safety switch can only be depressed while the lock bolt is withdrawn.

2.  Depress the life safety switch, located by the LIFE SAFETY label on the dead 

bolt, until it latches.

ATTENTION: 

To ensure engagement of the life safety switch, fully rotate the 

release knob counterclockwise and hold in that position. Then depress the life 
safety switch.

Once the Life Safety Feature is activated, the life safety switch blocks the lock bolt 
and prevents the dead bolt from latching when the door is closed.

TO DEACTIVATE THE LIFE SAFETY FEATURE

1.  Pull the life safety switch outward to release the bolt stop.

Summary of Contents for CDX-09

Page 1: ...CDX 09TM INSTALLATION OPERATING INSTRUCTIONS Please read all instructions carefully before putting your CDX 09 into operation...

Page 2: ...ATION 2 CDX 09 INSTALLATION 3 BASIC TOOLS NEEDED 3 INSTALLATION KIT CONTENTS 4 CDX 09 PARTS FOR INSTALLATION 5 STRIKE INSTALLATION 6 TEMPLATE 6 DEAD BOLT INSTALLATION 6 EXTERIOR MOUNTING PLATE INSTALL...

Page 3: ...s booklet for the X 09 Type 1F Lock P N 520 021 which is enclosed in this Operating Installation Instruction Kit Please refer also to the Model CDX 09 Lock System drawing P N 524 021 for lock nomencla...

Page 4: ...thdraw the lock bolt and also the dead bolt Extension Bolt Note The life safety switch can only be depressed while the lock bolt is withdrawn 2 Depress the life safety switch located by the LIFE SAFET...

Page 5: ...ium Phillip s screwdriver 1 2 2 Standard hacksaw 32 teeth inch 3 Small flat file 4 Small vise or a Port A Vise Harbor Freight P4742 5 Drill bits No 25 11 32 1 2 6 Electric hand drill 7 3 32 hexkey 8 1...

Page 6: ...al hub locating 10 Zebra Connector and Retainer 11 Cable Tie Clips 3 12 Dial ring to exterior mounting plate mounting screws pan head 8 32 x 5 16 2 Packaged with exterior mounting plate used with Non...

Page 7: ...ardplate 3 Dial hub assembly 4 Strike Kit 1 of 4 Types 1 2 3 or 9 Strike 9 is shown in photo with screws 5 Spindle 6 Dial ring assembly 7 Dial assembly 8 Exterior mounting plate cover 9 Exterior mount...

Page 8: ...ing and tape the template to the door 3 Center punch all hole positions onto the door 4 Drill the 1 2 diameter spindle hole through the door 5 Drill the two 2 CDX 09 attaching screw holes nearest the...

Page 9: ...r the two 2 8 32 x 5 16 machined screws Non Drill Resistant Mounting Plate that are provided 2 Refer to the section on installation of the dial ring in the INSTALLATION INSTRUCTIONS FOR THE X 09 TYPE...

Page 10: ...not be liable for technical errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material 2002 2008 Kaba Mas X 09 i...