7
12. Feed the cable and outer tube through the 1/2" hole in the door while
positioning the CDX-09 and hardplate against the door. Insert the two (2) #10
screws nearest the strike opening to attach the CDX-09 and hardplate to
the door.
13. Position the Exterior (Dial ring) Mounting Plate and insert the four (4) #10-32
x 1.25 pan head machine screws. Longer or shorter screws may be required
depending on door thickness as follows:
DOOR THICKNESS:
SCREW LENGTH:
1.25 1.00
1.375 - 1.75
1.25 (PROVIDED)
1.875 - 2.00
1.50
2.125 - 2.50
2.00
2.625 - 3.00
2.50
3.125 - 3.50
3.00
3.625 - 4.00
3.50
4.125 - 4.50
4.00
DIAL RING INSTALLATION
1. Place the Exterior (Dial ring) Mounting Plate Cover over the Exterior (Dial ring)
Mounting Plate and mount the dial ring using the two (2) #8 locknuts (Drill
Resistant Mounting Plate), or the two (2) #8-32 x 5/16 machined screws (Non-
Drill Resistant Mounting Plate) that are provided.
2. Refer to the section on installation of the dial ring in the “INSTALLATION
INSTRUCTIONS FOR THE X-09 TYPE 1F HIGH SECURITY ELECTRONIC
LOCK” booklet for additional dial ring installation instructions.
CUSTOM CUTTING TUBES AND SPINDLE
1. Refer to the sections for cutting tubes and for cutting the spindle in the
“INSTALLATION INSTRUCTIONS FOR THE X-09 TYPE 1F HIGH SECURITY
ELECTRONIC LOCK” booklet for detailed instructions needed to cut the tubes
and spindle to fi t your specifi c installation.
INSTALLATION COMPLETION INSTRUCTIONS
1. Continue to follow the instructions in the “INSTALLATION INSTRUCTIONS
FOR THE X-09 TYPE 1F HIGH SECURITY ELECTRONIC LOCK” booklet for
the remainder of the lock installation. Please note that when those instructions
refer to the
lock case assembly
, the installer should consider that as meaning
the
CDX-09 unit
.
DO NOT REMOVE THE X-09 LOCK CASE FROM THE CD BASE.