When only a single station operation is needed, the
user can manually start a specific station.
1. Use the PROGRAM SELECT BUTTON to select the
program (A, B or C) that contains the station you
wish to manually operate.
2. Turn the dial to RUN SINGLE STATION. Display
shows selected program and word “SINGLE.”
Press NEXT to enter single station operation.
3. Press UP or DOWN to select desired station.
4. Press MANUAL START to begin station operation.
NOTE:
Pressing BACK or NEXT buttons will manually
advance to the next or previous station number.
Previously programmed run times can be increased
or decreased during manual operation. Any run time
changes during manual operation WILL NOT
change the station’s stored program run time.
If station has a zero run time (OFF) use PROGRAM
SELECT BUTTON to select a different program.
Stations with a zero run time (OFF) can not be
manually activated. Only stations with a previously
programmed run time can be manually started.
Locating a valve in an irrigation system may be
needed for maintenance or repair. Without the
correct tools locating the valves can be time
consuming.
The Pro-LC controllers locate feature helps the user
find buried valves by pulsing the valves solenoid.
1. Turn the dial to RUN SINGLE STATION/SYSTEM
TEST. The display will show selected program
and “SINGLE.” Press the UP or DOWN buttons
until display shows “LOCATE.”
2. Press the MANUAL START button to begin the
locate feature. The display will now show the
available station.
3. Press the MANUAL START button to advance
to the next available station.
10
RUNNING A SINGLE STATION MANUALLY
VALVE LOCATOR
SINGLE
a
pgm