14. OTHERS
99
In the case of troubles occurring during operation of the GY-DV550, it performs a self-test to identify the cause and displays the
result in the form of an error code. The error code consists of the "main code" which indicates its contents and the "sub-code" which
indicates the details. Depending on the status of the GY-DV550 at this time, indications may also appear on the LCD display, the
WARNING indicator may activate and the alarm tone may be generated.
In the viewfinder, the "VTR WARNING (DEW)" indication appears when condensation is detected, and the "VTR WARNING (STOP)",
"VTR WARNING (HARD)" or "VTR WARNING (REW)" indication appears depending on the contents of the error code when some
of the other error codes are displayed.
* In the Auto OFF status, it is impossible to operate the GY-
DV550. This condition can be cancelled by switching the
OPERATE switch OFF and then switching it ON again. If the
same problem occurs again after the power is turned ON,
there may be something wrong with the GY-DV550. Please
consult the person in charge of professional video equipment
at your nearest JVC-authorized service agent.
* If the display operates abnormally, Press the RESET switch
inside the lithium battery case, and then set the OPERATE
switch to ON again. (
☞
See page 36)
Please note that pressing the RESET switch will also reset
the time code data and time and date data.
WARNING indicator
Alarm Tone
Display
GY-DV550 Operation
Red, blinking
Continuous
"Error code"
• Automatically ejects the cassette. It can be inserted again.
"Error code"
plus
"AUTO OFF"
• Automatically stops operation or ejects the cassette.
(Auto OFF) * The GY-DV550 does not accept any operation.
Red, blinking
Intermittent
"DEW "
• Dew condensation inside the unit.
The GY-DV550 does not accept any operation until the DEW indicator
disappears from the display.
14-1 Troubleshooting (Cont'd)
The GY-DV550 is a microcomputer-controlled piece of
equipment, which may malfunction due to external noise
or interference. In this case, set the OPERATE switch to
OFF, remove the lithium backup battery, and then set the
OPERATE switch to ON again after a few minutes.
SHUTTER STATUS
MENU
FILTER
3200k
1
5600k+1/8ND
2
5600k+1/64ND
3
ALARM
MONITOR
OPERATE
NG
GAIN
OUTPUT WHT.BA
L
VTR
ON
OFF
AUTO IRIS
LOLUX
BACK L
NORMAL
SPOT L
STRETCH
NORMAL
COMPRESS
LIGHT
ON
OFF
COUNTER
AUDIO SELECT
MANUAL
AUTO
CH-1
CH-2
CH-1
CH-2
REAR
FRONT
RM
AUDIO INPUT
MODE
CTL
TC
UB
CH-1
MIX
CH-2
RESET
OPERATE/WARNING
MONITOR
SELECT
CH-1
AUDIO
LEVEL
CH-2
VTR
ON
OFF
INCOM
MIC
INCOM
MIC
LEVEL
POWER
OFF
RM
DC IN
/BATT.
CALL
CARBON
DYNAMIC
FULL AUTO
BLACK
VTR WARNING (HARD)
VTR WARNING (DEW)
AUTO OFF
DEW
Main code
Dew condensation
indicator
Sub-code
ALARM
tone
EARPHONE
TALLY lamp
WARNING indicator
TALLY
lamp
Auto-OFF indicator:
Lights depending on the error
code. When this indicator
lights, the GY-DV550 will
automatically stop operation or
eject the cassette.
The GY-DV550 does not accept
any operation.