3.2.3 ASSEMBLY/DISASSEMBLY OF [4] MONITOR ASSEMBLY
z
CAUTIONS
(1) During the procedure, be careful in handling the LCD
MODULE and other parts. Pay special attention not to
damage or soil the monitor screen.
If fingerprints are left on the screen, wipe them with clean
chamois leather or a cleaning cloth.
z
Removing MONITOR ASSEMBLY
(1) Turn the HINGE UNIT ASSEMBLY 90
°
, and remove the
two screws (1 and 2). Remove the M.COVER ASSY by
removing the six hooks (L4a-f).
(2) Pull out the U/D SWITCH BOARD from the MONITOR
CASE ASSEMBLY.
NOTE4a:
During the procedure, be careful in handling the FPC.
(3) Release the lock of the connector (CN4a), and remove
the HINGE UNIT by lifting it up.
(4) Release the lock of the connector (CN4b), and pull out
the FPC.
(5) Remove the screw (3), and Remove the MONI PWB
ASSY by removing the hook (L4g).
NOTE4b:
When attaching the MONITOR BOARD ASSEMBLY,
be careful to avoid any misalignment or unevenness of
the parts underneath.
(6) Remove the SHEET (M.REF), LIGHT GUIDE, SHEET
(M.DIFF) and the SHEET(BEF).
(7) Remove the S.CASE(MONI), LCD MODULE and the
LCD CASE.
NOTE4c:
During the procedure, handle the three parts (LCD
CASE, LCD MODULE, and S.CASE(MONI)) together.
z
Removing HINGE UNIT ASSEMBLY
(1) Remove the screw (4), and Remove the H.COVER(U,L).
NOTE4d:
During the procedure, be careful in handling the mag-
net.
When attaching, set the negative pole outside as
shown in the figure. Be careful when removing as
there is no marking.
NOTE4e:
During the procedure, be careful in handling the FPC.
NOTE4f:
The FPC is rolled around the axis of rotation of the
HINGE ASSEMBLY 2.5 rounds (2.5times).
The connecting side to the MONITOR BOARD AS-
SEMBLY is placed inside.
36
(S14)
L14b
L14a
38
(S14)
37
(S14)
[14]
m
m
n
n
m
n
39
(S15)
40
(S16)
41
(S16)
43
(S16)
CN15a
L15b
L15a
CN15e
CN15d
CN15c
CN15b
[15]
[15]
<MECHANISM SIDE>
[16]
r
q
p
n
o
o
n
p
q
r
42
(S16)
0.088N
m(0.9kgf
cm)