63
ENGLISH
Replacing the Light-source Lamp (Cont.)
Resetting the Lamp Use Time
After replacing with a new light-source lamp, reset the counter inside the projector. This works to reset the life calculation of the
light-source lamp, allowing the used time of the new light-source lamp to be accumulated.
1
Turn on the MAIN POWER switch
to go into stand-by mode.
• ON [
❙
]:The main power turns ON and the STAND BY
indicator lights.
2
Press and hold down the “VIDEO”,
“SETTING” and “QUICK ALIGN. +
3
” at the same time for six
seconds or more.
• The STAND BY and OPERATE indicators come on at
the same time.
3
While the STAND BY and
OPERATE indicators are on,
press the “VIDEO”, “SETTING”,
and “COMPUTER” buttons at the
same time.
• The STAND BY and OPERATE indicators blink two
seconds alternately, and after blinking, the projector
returns to stand-by state (the STAND BY indicator lights).
* This completes the resetting of the lamp use time.
Memo
To check the lamp use time has been reset :
You can check it by LAMP TIME on the OPTIONS menu.
CAUTIONS
• After replacing with a new light-source lamp, be sure to
reset the lamp use time. When the lamp use time
indicates 1000 hours, and if it is not reset, the projector
does not operate. (The light-source lamp does not turn
on.)
• Reset the lamp use time only when you have replaced
with a new light-source lamp. Never reset it at a halfway
time. Otherwise, the replacement time may become
unclear, degrade performance markedly, or cause lamp
explosion.
■
Projector’s button
[MAIN POWER switch]
[Control panel]
1
3
2
STAND BY indicator
OPERATE indicator
STAND BY
LAMP
TEMP
EMERGENCY
VIDEO
COMPUTER
SETTING
QUICK
ALIGN.
-
2
+
3
M20U p.60-71
00.6.15, 8:21 PM
63