- 7 -
EMC precaution
• This product requires special EMC precautions and needs to be installed and used
according to the following information.
• Use the specified cable. Using other cables could increase emission or decrease
immunity.
• Do not place any RF communication equipment in the vicinity of this product. It could
affect the performance of the product.
• Any additional equipment connected to this product needs to comply with the
requirements of IEC/EN60601-1-2.
Guidance and manufacturer’s declaration – electromagnetic emissions
The model CL-S200 is intended for use in the electromagnetic environment specified below. The
customer or the user of the model CL-S200 should assure that it is used in such an
environment.
Emissions test
Compliance
Electromagnetic environment
– guidance
RF emissions CISPR 11
Group 1
The model CL-S200 uses RF energy
only for its internal function. Therefore,
its RF emissions are very low and are
not likely to cause any interference in
nearby electronic equipment.
RF emissions CISPR 11
Class B
The model CL-S200 is suitable for use in
all establishments, including domestic
establishments and those directly
connected to the public low-voltage
power supply network that supplies
buildings used for domestic purposes.
Harmonic emissions
IEC 61000-3-2
Class D
Voltage fluctuations/flicker
emissions
IEC 61000-3-3
Complies
Recommended separation distances between
portable and mobile RF communications equipment and the model CL-S200
The model CL-S200 is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The customer or the user of the model CL-S200 can help prevent
electromagnetic interference by maintaining a minimum distance between portable and mobile
RF communications equipment (transmitters) and the model CL-S200 as recommended below,
according to the maximum output power of the communications equipment.
Rated maximum
output power of
transmitter
W
Separation distance according to frequency of transmitter
m
150 kHz to 80 MHz
d
= 1.2
80 MHz to 800 MHz
d
= 1.2
800 MHz to 2.7 GHz
d
= 2.3
0.01
0.12
0.12
0.23
0.1
0.38
0.38
0.73
1
1.2
1.2
2.3
10
3.8
3.8
7.3
100
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended
separation distance
d
in meters (m) can be estimated using the equation applicable to the
frequency of the transmitter, where
P
is the maximum output power rating of the transmitter in
watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range
applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is
affected by absorption and reflection from structures, objects and people.