Errata
67
Release 10.3.2
The tables in the
Interface Types and Specifiers
section of
Chapter 1, Command
Reference Topics
, in the
JunosE Command Reference Guide
erroneously state that
the maximum number of PPPoE subinterfaces per Ethernet (GE/FE) line
module is 4094. The correct number for an ERX router is 8000 and for an E120
or E320 router, it is 16,000.
The
JunosE Command Reference Guide N to Z
omits the description of the
show
memory-management protection
command, beginning with JunosE Release
7.1.0 in which it was introduced.
The
show memory-management protection
command is available in
Privileged Exec mode. You can use this command to display the information
about memory management protection of the router.
The syntax for this command is:
show memory-management protection [detail] [
filter
]
The command can be used only in the support mode and is not user
configurable.
In the
JunosE System Event Logging Reference Guide,
for the
radiusClient
event
category, the Error field incorrectly includes the following errors:
Internal allocation error of base RADIUS server table
Invalid virtual router for user's context
These errors were never implemented in any version of JunosE Software.