Figure 86: Installing a M120 XENPAK Module
Related
Documentation
M120 Router Chassis Description on page 6
•
•
Overview of Troubleshooting Resources for the M120 Router on page 117
Replacing M120 Power System Components
To replace a power system component, perform the following procedures:
•
Replacing an M120 AC Power Supply on page 173
•
Replacing an M120 DC Power Supply on page 177
•
Replacing an M120 AC Power Supply Cord on page 182
•
Replacing an M120 DC Power Supply Cable on page 183
Replacing an M120 AC Power Supply
In the AC power configuration, the router has two AC power supplies (see Figure 14 on
page 30), located at the rear of the chassis in slots
PEM0
and
PEM1
(left to right). Each
AC power supply provides power to all components in the router. The AC power supplies
are fully redundant and current is shared almost equally in a fully configured system. In
a fully configured router, if one power supply fails or is removed, the remaining power
supply instantly assumes the entire electrical load.
Each power supply (AC or DC) is hot-insertable and hot-removable.