Table 10: JATP400 Appliance Physical Specifications
(Continued)
Specification
JATP400
Non-operating temperature
-40° F (-40° C) to 158° F (70° C)
Operating relative humidity
8% - 90% noncondensing
Non-operating relative
humidity
5% - 95% noncondensing
Operating altitude
6500 ft max.
Maximum thermal output
1002.2 BTU/hour
JATP400 Appliance Rack and Clearance Requirements
You can install the JATP400 appliance in a four-post rack.
provides the requirements for rack size, clearance, airflow, spacing of mounting
brackets and flange holes, and connecting to the building structure.
Table 11: Rack and Clearance Requirements for the JATP400 Appliance
Rack Requirement
Specifications
Size
A 19-in. (48.3 cm) rack as defined in Cabinets, Racks, Panels, and Associated
Equipment (document number EIA-310-D) published by the Electronics Industry
Association (http://www.eia.org).
Clearance
• The outer edges of the mounting brackets extend the width of chassis on
both sides to 19-in. (48.3 cm).
• The front of the chassis extends approximately 1.5-in. (3.8 cm) beyond the
mounting ears.
20
Summary of Contents for JATP400
Page 1: ...JATP400 Appliance Hardware Guide Published 2021 05 17...
Page 8: ...1 CHAPTER Overview JATP400 System Overview 2 JATP400 Chassis 4...
Page 64: ...The hard drive pops partially out of the slot 57...
Page 65: ...Figure 24 Removing a Drive Carrier g100245 58...
Page 67: ...5 CHAPTER Troubleshooting Hardware Contacting Juniper Networks Technical Assistance Center 61...
Page 69: ...6 CHAPTER Returning the Chassis or Components Returning the JATP400 Chassis or Components 63...
Page 72: ...Maintaining the JATP400 Hard Disk Drive 56 65...